LEYBOLD
Leybold Large ISO Right-Angle Vacuum Valve DN250–DN1000
- Sizes
- DN250, 320, 400, 500, 630, 800, 1000
- Conductance, listed size order
- 2500 / 4100 / 6300 / 10500 / 16500 / 29400 / 46900 l/s
- Helium leak rate
- 1 × 10⁻⁹ mbar l/s
LEYBOLD brand guide / Product family
Select Leybold angle, safety, dosing and venting valves by flange, pressure range, seal material and actuation. Compare documented configurations for laboratory and industrial vacuum.
| Specification | Details |
|---|---|
| Leybold LEYCON BAV Manual ISO-K Angle Valve | DN63 / DN100 / DN160 ISO-K |
| Leybold LEYCON BAV Pneumatic ISO-K Angle Valve | DN63 / DN100 / DN160 ISO-K |
| Leybold LEYCON SECUVAC ISO-KF Safety Valve | DN16 / DN25 / DN40 ISO-KF |
| Leybold LEYCON SECUVAC ISO-K Safety Valve | DN63 / DN100 ISO-K |
| Leybold LEYCON EV 016 DOS AB Dosing Valve | DN16 ISO-KF |
| Leybold LEYCON DN10 Power-Failure Venting Valve | DN10 ISO-KF |
| Leybold Large ISO Right-Angle Vacuum Valve DN250–DN1000 | DN250, 320, 400, 500, 630, 800, 1000 |
BAV angle valves isolate a line manually or remotely. SECUVAC combines pump-side venting with system isolation on power loss. EV 016 meters gas into a vacuum system, while the DN10 power-failure valve opens when de-energised. Large ISO angle valves serve industrial lines and require controlled pressure equalisation before opening.
Working pressure, opening differential, housing leak rate and seat leak rate describe different properties. Keep them separate when comparing valves. Conductance also differs from a pump’s pumping speed. Select elastomers, body material, bakeout limits and cleanliness for the gas and vacuum level.
Specify manual, pneumatic or electropneumatic operation, fail position, compressed-air pressure and pilot voltage. Check both flange faces and mounting orientation. DN250–1000 industrial valves need the cylinder at the top and have size-specific opening differential limits.
Explore TURBOVAC i/iX pumps and DRYVAC dry screw pumps when planning complete pumping lines. Further gate, all-metal UHV and specialist valves can be selected by enquiry against a confirmed drawing and order reference.
Each product page links to the relevant operating instructions and retains the conditions on the published specifications. Send the process, working pressure, flow, connections and utilities for a configured quotation. Explore the Leybold brand guide for related ranges.
Compare values with their stated gas, frequency and configuration conditions. A blank specification means it needs confirmation. Listed equipment is subject to a quotation; inclusion here does not indicate stock.
| Model | Sizes | Conductance, listed size order | Helium leak rate | Actuation |
|---|---|---|---|---|
| Leybold Large ISO Right-Angle Vacuum Valve DN250–DN1000 | DN250, 320, 400, 500, 630, 800, 1000 | 2500 / 4100 / 6300 / 10500 / 16500 / 29400 / 46900 l/s | 1 × 10⁻⁹ mbar l/s | Confirm for this model |
| Leybold LEYCON BAV Manual ISO-K Angle Valve | DN63 / DN100 / DN160 ISO-K | Confirm for this model | Confirm for this model | Manual handwheel |
| Leybold LEYCON BAV Pneumatic ISO-K Angle Valve | DN63 / DN100 / DN160 ISO-K | Confirm for this model | Confirm for this model | Pneumatic or electropneumatic; normally closed |
| Leybold LEYCON DN10 Power-Failure Venting Valve | Confirm for this model | Confirm for this model | Confirm for this model | Confirm for this model |
| Leybold LEYCON EV 016 DOS AB Dosing Valve | Confirm for this model | Confirm for this model | Confirm for this model | Confirm for this model |
| Leybold LEYCON SECUVAC ISO-KF Safety Valve | DN16 / DN25 / DN40 ISO-KF | Confirm for this model | Confirm for this model | Confirm for this model |
| Leybold LEYCON SECUVAC ISO-K Safety Valve | DN63 / DN100 ISO-K | Confirm for this model | Confirm for this model | Confirm for this model |

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD
Open the model page for its specifications and available manufacturer downloads. Match the full model, suffix and revision to the equipment being supplied. Keep installation limits and performance test conditions with the figure when comparing alternatives.
Return to the LEYBOLD brand guide · Explore all product families
Send the process, working pressure, gas, required capacity and electrical supply. For measurement, include the range, connection, output and controller. We can confirm the model, accessories and documentation for your quotation.
Compare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino