LEYBOLD
Leybold RUVAC WA / WAU 251 Roots Vacuum Booster
- Nominal displacement at 50 Hz
- 253 m³/h
- Nominal connection size
- DN 63; flange standard confirmed for version
- Motor rating
- 1.1 kW; confirm selected motor
LEYBOLD brand guide / Product family
A RUVAC booster works between the chamber and a backing pump. It can increase pumping capacity in the appropriate pressure region, but cannot exhaust independently to atmosphere. Size the combination from gas load, operating pressure and required evacuation time.
WA uses a standard motor and needs the correct start sequence and differential-pressure protection. WAU adds an integrated pressure-equalisation bypass. Both need a correctly sized backing pump, suitable drive and process protection. Other RUVAC motor families, including WS/WSU and WH/WHU, require separate specification.
| Specification | Details |
|---|---|
| 251 | 253 m³/h at 50 Hz; DN63 nominal |
| 501 | 505 m³/h at 50 Hz; DN63 nominal |
| 1001 | 1000 m³/h at 50 Hz; DN100 nominal |
| 2001 | 2050 m³/h at 50 Hz; DN160 nominal |
These are nominal displacements, not chamber pumping speeds. Effective performance and ultimate pressure depend on the complete system. Manufacturer documents differ on flange standard; confirm the order-specific flange drawing before purchasing mating hardware.
SOGEVAC oil-sealed backing pumps · DRYVAC dry screw pumps · Coating and deposition · Drying and degassing
Provide the duty, gas composition, pressure profile, cycle time, supply and existing backing pump. Price, availability, lubricant, motor and controls are confirmed in the quotation.
Compare values with their stated gas, frequency and configuration conditions. A blank specification means it needs confirmation. Listed equipment is subject to a quotation; inclusion here does not indicate stock.
| Model | Nominal displacement at 50 Hz | Nominal connection size | Motor rating |
|---|---|---|---|
| Leybold RUVAC WA / WAU 251 Roots Vacuum Booster | 253 m³/h | DN 63; flange standard confirmed for version | 1.1 kW; confirm selected motor |
| Leybold RUVAC WA / WAU 501 Roots Vacuum Booster | 505 m³/h | DN 63; flange standard confirmed for version | 2.2 kW; confirm selected motor |
| Leybold RUVAC WA / WAU 1001 Roots Vacuum Booster | 1000 m³/h | DN 100; flange standard confirmed for version | 4 kW; confirm selected motor |
| Leybold RUVAC WA / WAU 2001 Roots Vacuum Booster | 2050 m³/h | DN 160; flange standard confirmed for version | 7.5 kW; confirm selected motor |

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD
Open the model page for its specifications and available manufacturer downloads. Match the full model, suffix and revision to the equipment being supplied. Keep installation limits and performance test conditions with the figure when comparing alternatives.
Return to the LEYBOLD brand guide · Explore all product families
Send the process, working pressure, gas, required capacity and electrical supply. For measurement, include the range, connection, output and controller. We can confirm the model, accessories and documentation for your quotation.
Compare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino