
LEYBOLD
Leybold SOGEVAC SV 10 B Single-Stage Rotary Vane Vacuum Pump
- Ordering options
- 3 manufacturer codes — see configuration table
LEYBOLD brand guide / Product family
The expanded selection includes smaller B and D models, BI variants, larger B/BF pumps, SV 570 B and FP configurations. Match motor supply, lubricant, gas ballast and cooling to the selected build.
Verified manufacturer ordering references are listed on the product pages. For configured equipment, the final code is confirmed with the quotation.
Find Leybold filters, maintenance kits, replacement parts and LEYBONOL
Compare SV220 B, SV300 B and SV320 B industrial oil-sealed pumps, with configuration-specific motors, gas ballast and cooling.
| Specification | Details |
|---|---|
| Leybold SOGEVAC SV220 B Single-Stage Rotary Vane Vacuum Pump | 179 / 214 m³/h actual |
| Leybold SOGEVAC SV300 B Single-Stage Rotary Vane Vacuum Pump | 240 / 290 m³/h actual |
| Leybold SOGEVAC SV320 B Single-Stage Rotary Vane Vacuum Pump | 284 / 330 m³/h actual |
Actual pumping speed and nominal displacement are different figures. SV220 B is rated at 179 / 214 m³/h, SV300 B at 240 / 290 m³/h and SV320 B at 284 / 330 m³/h actual speed at 50 / 60 Hz in the current instructions. The individual pages retain the relevant pressure terminology and motor-build conditions.
Specify gas ballast around vapour load, then choose motor supply, cooling, lubricant and connection fittings. The SV300 manual labels its lowest pressure as partial pressure; do not compare it unqualified with total-pressure figures. SV320 motor and ambient ratings require a build-specific check.
Provide working pressure, required flow, gas composition, vapour and dust loads, operating hours, available three-phase supply and cooling conditions. Allow exhaust-filter replacement and ventilation space. Select oil, filtration and exhaust treatment around the process.
For dry compression, compare Leybold NOVADRY and VARODRY; suitability depends on the operating envelope and gas load.
Compare values with their stated gas, frequency and configuration conditions. A blank specification means it needs confirmation. Listed equipment is subject to a quotation; inclusion here does not indicate stock.
| Model | Ordering options | End / ultimate pressure | Electrical supply | Pumping speed, 50 / 60 Hz |
|---|---|---|---|---|
| Leybold SOGEVAC SV 10 B Single-Stage Rotary Vane Vacuum Pump | 3 manufacturer codes — see configuration table | Confirm for this model | Confirm for this model | Confirm for this model |
| Leybold SOGEVAC SV 16 B Single-Stage Rotary Vane Vacuum Pump | 7 manufacturer codes — see configuration table | Confirm for this model | Confirm for this model | Confirm for this model |
| Leybold SOGEVAC SV 16 D Single-Stage Rotary Vane Vacuum Pump | 16 manufacturer codes — see configuration table | Confirm for this model | Confirm for this model | Confirm for this model |
| Leybold SOGEVAC SV 25 B Single-Stage Rotary Vane Vacuum Pump | 12 manufacturer codes — see configuration table | Confirm for this model | Confirm for this model | Confirm for this model |
| Leybold SOGEVAC SV 25 D Single-Stage Rotary Vane Vacuum Pump | 14 manufacturer codes — see configuration table | Confirm for this model | Confirm for this model | Confirm for this model |
| Leybold SOGEVAC SV 28 BI Single-Stage Rotary Vane Vacuum Pump | 2 manufacturer codes — see configuration table | Confirm for this model | Confirm for this model | Confirm for this model |
| Leybold SOGEVAC SV 40 B Single-Stage Rotary Vane Vacuum Pump | 32 manufacturer codes — see configuration table | Confirm for this model | Confirm for this model | Confirm for this model |
| Leybold SOGEVAC SV 55 BI2 Single-Stage Rotary Vane Vacuum Pump | 1 manufacturer code — see configuration table | Confirm for this model | Confirm for this model | Confirm for this model |
| Leybold SOGEVAC SV 65 B Single-Stage Rotary Vane Vacuum Pump | 26 manufacturer codes — see configuration table | Confirm for this model | Confirm for this model | Confirm for this model |
| Leybold SOGEVAC SV 100 B Single-Stage Rotary Vane Vacuum Pump | 35 manufacturer codes — see configuration table | Confirm for this model | Confirm for this model | Confirm for this model |
| Leybold SOGEVAC SV 120 B Single-Stage Rotary Vane Vacuum Pump | 10 manufacturer codes — see configuration table | Confirm for this model | Confirm for this model | Confirm for this model |
| Leybold SOGEVAC SV220 B Single-Stage Rotary Vane Vacuum Pump | 7 manufacturer codes — see configuration table | ≤0.08 mbar ultimate total pressure, gas ballast closed | Three-phase; configuration-specific voltage | 179 / 214 m³/h actual |
| Leybold SOGEVAC SV300 B Single-Stage Rotary Vane Vacuum Pump | 49 manufacturer codes — see configuration table | ≤0.08 mbar ultimate partial pressure, gas ballast closed | Three-phase; configuration-specific voltage | 240 / 290 m³/h actual |
| Leybold SOGEVAC SV320 B Single-Stage Rotary Vane Vacuum Pump | 6 manufacturer codes — see configuration table | ≤0.08 mbar ultimate total pressure, gas ballast closed | Three-phase; configuration-specific voltage | 284 / 330 m³/h actual |
| Leybold SOGEVAC SV 320 FP Single-Stage Rotary Vane Vacuum Pump | 3 manufacturer codes — see configuration table | Confirm for this model | Confirm for this model | Confirm for this model |
| Leybold SOGEVAC SV 570 B Single-Stage Rotary Vane Vacuum Pump | Confirm for this model | Confirm for this model | Confirm for this model | Confirm for this model |
| Leybold SOGEVAC SV 630 B/BF Single-Stage Rotary Vane Vacuum Pump | 39 manufacturer codes — see configuration table | Confirm for this model | Confirm for this model | Confirm for this model |
| Leybold SOGEVAC SV 750 B/BF Single-Stage Rotary Vane Vacuum Pump | 15 manufacturer codes — see configuration table | Confirm for this model | Confirm for this model | Confirm for this model |

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD
Open the model page for its specifications and available manufacturer downloads. Match the full model, suffix and revision to the equipment being supplied. Keep installation limits and performance test conditions with the figure when comparing alternatives.
Return to the LEYBOLD brand guide · Explore all product families
Send the process, working pressure, gas, required capacity and electrical supply. For measurement, include the range, connection, output and controller. We can confirm the model, accessories and documentation for your quotation.
Compare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino