LEYBOLD
Leybold COMBIVAC CM 51 Vacuum Gauge Controller
- Measurement channels
- 2 passive THERMOVAC + 1 passive PENNINGVAC
- Compatible Pirani heads
- TR 211, TR 212, TR 216
- Compatible high-vacuum heads
- PR 25, PR 26, PR 27, PR 28
LEYBOLD brand guide / Product family
GRAPHIX ONE, TWO and THREE read active transmitters. COMBIVAC CM 51 and CM 52 operate specified passive sensor heads.
GRAPHIX ONE, TWO and THREE provide one, two or three active-transmitter channels. COMBIVAC CM 51 and CM 52 operate specified passive sensor heads. These are different system architectures. Identify every sensor part number, channel, cable and output before selecting a controller, and specify the correct UK mains lead.
Identify every sensor, cable and interface. Active and passive systems are not interchangeable; specify the UK mains lead.
Compare values with their stated gas, frequency and configuration conditions. A blank specification means it needs confirmation. Listed equipment is subject to a quotation; inclusion here does not indicate stock.
| Model | Measurement channels | Compatible Pirani heads | Compatible high-vacuum heads | Display range |
|---|---|---|---|---|
| Leybold COMBIVAC CM 51 Vacuum Gauge Controller | 2 passive THERMOVAC + 1 passive PENNINGVAC | TR 211, TR 212, TR 216 | PR 25, PR 26, PR 27, PR 28 | Confirm for this model |
| Leybold COMBIVAC CM 52 Vacuum Gauge Controller | 2 passive THERMOVAC + 1 passive IONIVAC | TR 211, TR 212, TR 216 | IE 414 Bayard–Alpert or IE 514 extractor | Confirm for this model |
| Leybold GRAPHIX ONE Vacuum Gauge Controller | 1 active-gauge channel | Confirm for this model | Confirm for this model | 1 × 10⁻¹⁰–2000 mbar; actual measurement range depends on connected sensor |
| Leybold GRAPHIX THREE Vacuum Gauge Controller | 3 active-gauge channels | Confirm for this model | Confirm for this model | 1 × 10⁻¹⁰–2000 mbar; actual measurement range depends on connected sensor |
| Leybold GRAPHIX TWO Vacuum Gauge Controller | 2 active-gauge channels | Confirm for this model | Confirm for this model | 1 × 10⁻¹⁰–2000 mbar; actual measurement range depends on connected sensor |

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD
Open the model page for its specifications and available manufacturer downloads. Match the full model, suffix and revision to the equipment being supplied. Keep installation limits and performance test conditions with the figure when comparing alternatives.
Return to the LEYBOLD brand guide · Explore all product families
Send the process, working pressure, gas, required capacity and electrical supply. For measurement, include the range, connection, output and controller. We can confirm the model, accessories and documentation for your quotation.
Compare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino