LEYBOLD
End / ultimate pressure <0.03 mbar without gas ballast
Electrical supply Single-phase 100–120 V or 200–240 V ±10%, 50/60 Hz; separate order codes
Maximum pumping speed 55 m³/h on air, without gas ballast; ±5% Compare View specifications → LEYBOLD
End / ultimate pressure <0.03 mbar without gas ballast
Electrical supply Single-phase 100–120 V or 200–240 V ±10%, 50/60 Hz; separate order codes
Maximum pumping speed 55 m³/h on air, without gas ballast; ±5%; up to 52 m³/h on helium Compare View specifications → LEYBOLD
End / ultimate pressure 0.1 mbar without gas ballast
Electrical supply Three-phase, version-specific: 200/400 V ±10% at 50 Hz; 230/460 V or 200/380 V ±10% at 60 Hz
Maximum pumping speed 65 m³/h without gas ballast; ±5%, C5 manual Compare View specifications → LEYBOLD
End / ultimate pressure 0.1 mbar without gas ballast
Electrical supply Three-phase, version-specific: 200/400 V ±10% at 50 Hz; 230/460 V or 200/380 V ±10% at 60 Hz
Maximum pumping speed 105 m³/h without gas ballast; ±5%, C5 manual Compare View specifications → LEYBOLD
End / ultimate pressure 0.1 mbar without gas ballast
Electrical supply Three-phase, version-specific: 200/400 V ±10% at 50 Hz; 230/460 V or 200/380 V ±10% at 60 Hz
Maximum pumping speed 155 m³/h without gas ballast; ±5%, C5 manual Compare View specifications → LEYBOLD
End / ultimate pressure 0.1 mbar without gas ballast
Electrical supply Three-phase, version-specific: 200/400 V ±10% at 50 Hz; 230/460 V or 200/380 V ±10% at 60 Hz
Maximum pumping speed 185 m³/h without gas ballast; ±5%, C5 manual Compare View specifications → LEYBOLD
End / ultimate pressure 0.01 mbar without gas ballast
Electrical supply Three-phase, version-specific: 200/400 V ±10% at 50 Hz; 230/460 V or 200/380 V ±10% at 60 Hz
Maximum pumping speed 65 m³/h without gas ballast; ±5%, C5 manual Compare View specifications → LEYBOLD
End / ultimate pressure 0.01 mbar without gas ballast
Electrical supply Three-phase, version-specific: 200/400 V ±10% at 50 Hz; 230/460 V or 200/380 V ±10% at 60 Hz
Maximum pumping speed 155 m³/h without gas ballast; ±5%, C5 manual Compare View specifications → LEYBOLD
End / ultimate pressure 0.01 mbar without gas ballast
Electrical supply Three-phase, version-specific: 200/400 V ±10% at 50 Hz; 230/460 V or 200/380 V ±10% at 60 Hz
Maximum pumping speed 185 m³/h without gas ballast; ±5%, C5 manual Compare View specifications → LEYBOLD
Peak speed: 1-phase 50/60 Hz or 3-phase 60 Hz 6.1 m³/h
Ordering options 6 manufacturer codes — see configuration table
Peak speed: 3-phase 50 Hz 5.1 m³/h Compare View specifications → LEYBOLD
Peak speed: 1-phase 50/60 Hz or 3-phase 60 Hz 20 m³/h
Ordering options 6 manufacturer codes — see configuration table
Peak speed: 3-phase 50 Hz 16.7 m³/h Compare View specifications → LEYBOLD
Peak speed: 1-phase 50/60 Hz or 3-phase 60 Hz 14.5 m³/h
Ordering options 6 manufacturer codes — see configuration table
Peak speed: 3-phase 50 Hz 12.6 m³/h Compare View specifications → Select a dry technology ECODRY plus covers clean-gas laboratory roughing and backing, including a separate helium-recovery version. SCROLLVAC plus provides compact scroll pumping with configuration-dependent performance. NOVADRY and VARODRY extend the choice to air-cooled industrial dry screw pumps. Dry compression does not remove maintenance or process-compatibility requirements.