Home / Medium Vacuum Pump / Dry Vacuum Pumps / Dry Multistage Roots Vacuum PumpsGirovac equipment catalogue
Dry Multistage Roots Vacuum Pumps Dry multistage Roots pumps provide oil-free compression for clean-gas roughing and backing. Leybold ECODRY 25/35 plus and 40/65 plus use different platforms: check pressure, speed, connections, power and installation limits on each model page.
The ECODRY 65 plus is rated at 55 m³/h maximum air pumping speed without gas ballast. The separate ECODRY 65 He plus is designed for helium recovery and recirculation with enhanced leak tightness; it has no gas-ballast valve for condensable vapours.
Compare the ECODRY plus family using working pressure, gas throughput, cycle frequency and electrical supply.
EDWARDS
Electrical supply 100–127 / 200–240 V ±10%, switchable single-phase, 50/60 Hz
Peak pumping speed 60 m³/h
Ultimate total pressure 0.03 mbar Compare View specifications → EDWARDS
Electrical supply 100–127 / 200–240 V ±10%, switchable single-phase, 50/60 Hz
Peak pumping speed 90 m³/h
Ultimate total pressure 0.03 mbar Compare View specifications → EDWARDS
Electrical supply 100–127 / 200–240 V ±10%, switchable single-phase, 50/60 Hz
Peak pumping speed 120 m³/h
Ultimate total pressure 0.03 mbar Compare View specifications → EDWARDS
Electrical supply 100–127 / 200–240 V ±10%, switchable single-phase, 50/60 Hz
Peak pumping speed 40 m³/h
Ultimate total pressure 0.03 mbar Compare View specifications → EDWARDS
Electrical supply 100–127 / 200–240 V ±10%, switchable single-phase, 50/60 Hz
Peak pumping speed 30 m³/h
Ultimate total pressure 0.03 mbar Compare View specifications → LEYBOLD
End / ultimate pressure <0.03 mbar without gas ballast
Electrical supply Single-phase 100–120 V or 200–240 V ±10%, 50/60 Hz; separate order codes
Maximum pumping speed 40 m³/h on air, without gas ballast; ±5% Compare View specifications → LEYBOLD
End / ultimate pressure <0.03 mbar without gas ballast
Electrical supply Single-phase 100–120 V or 200–240 V ±10%, 50/60 Hz; separate order codes
Maximum pumping speed 55 m³/h on air, without gas ballast; ±5% Compare View specifications → LEYBOLD
End / ultimate pressure <0.03 mbar without gas ballast
Electrical supply Single-phase 100–120 V or 200–240 V ±10%, 50/60 Hz; separate order codes
Maximum pumping speed 55 m³/h on air, without gas ballast; ±5%; up to 52 m³/h on helium Compare View specifications → LEYBOLD
Electrical supply Single-phase 100–127 or 200–240 V AC ±10%, 50/60 Hz
Maximum pumping speed 35 m³/h at standard ambient temperature and pressure
Typical ultimate pressure 0.01 mbar Compare View specifications → LEYBOLD
Electrical supply Single-phase 100–127 or 200–240 V AC ±10%, 50/60 Hz
Maximum pumping speed 25 m³/h at standard ambient temperature and pressure
Ordering options 1 manufacturer code — see configuration table Compare View specifications → Explore brand-specific ranges Use a family guide to compare models and understand the range before selecting a product.
Need help choosing equipment? Send the operating requirements and process details. For a replacement, include the existing model and connection.