LEYBOLD
Leybold VARODRY SYSTEM VDi 400 Dry Screw Vacuum Pump
- Ordering options
- 2 manufacturer codes — see configuration table
The VARODRY VD 65 is an air-cooled dry screw vacuum pump for industrial roughing, drying, degassing and suitable backing duties requiring a lower ultimate pressure. The manufacturer’s C5 operating instructions specify 65 m³/h maximum pumping speed without gas ballast and 0.01 mbar ultimate pressure without gas ballast.
Leybold VARODRY manufacturer range photograph showing the enclosed pump; motor and configuration depend on the model ordered.
Part of the Leybold VARODRY pumps and VDi systems family. Compare the range and other model options.
Tell us the configuration and quantity you need. Include your process requirements if you would like help with selection.
View quote listQuote the complete Leybold ordering code when requesting a price. The entries below identify different configurations; voltage, flange, lubricant, cooling and interfaces must match the installation. Availability and supplied equipment are confirmed with the quotation.
| Product code | Manufacturer designation | Configuration detail |
|---|---|---|
| 111065V10 | VARODRY VD 65 – 400V 50Hz | See designation and selected-code documentation |
| 111065V11 | VARODRY VD 65 – 230/460V 60Hz | See designation and selected-code documentation |
| 111065V12 | VARODRY VD 65 OEM – 50Hz 200/400V | See designation and selected-code documentation |
| 111065V13 | VARODRY VD 65 OEM – 60Hz 230/460V | See designation and selected-code documentation |
| 111065V15 | VARODRY VD 65 – 400V 50Hz, PURGE | See designation and selected-code documentation |
| 111065V16 | VARODRY VD 65 – 230/460V 60Hz, PURGE | See designation and selected-code documentation |
| 111065V21 | VARODRY VD 65 – 200/380V 60Hz | See designation and selected-code documentation |
| 111065V22 | VARODRY VD 65 OEM – 60Hz 200/380V | See designation and selected-code documentation |
| 111065V26 | VARODRY VD 65 -200/380V 60Hz, PURGE | See designation and selected-code documentation |
| 111065V35 | VARODRY VD 65 – HD/O2 50Hz 200/400V Purge | See designation and selected-code documentation |
| 111065V36 | VARODRY VD 65 – HD/O2 60Hz 230/460V Purge | See designation and selected-code documentation |
| 111065V45 | VARODRY VD 65 OEM HD/O2, 50Hz, 200/400 V | See designation and selected-code documentation |
| 111065V46 | VARODRY VD 65 OEM HD/O2, 60Hz, 230/460 V | See designation and selected-code documentation |
The VARODRY VD 65 is an air-cooled dry screw vacuum pump for industrial roughing, drying, degassing and suitable backing duties requiring a lower ultimate pressure. The manufacturer’s C5 operating instructions specify 65 m³/h maximum pumping speed without gas ballast and 0.01 mbar ultimate pressure without gas ballast.
The 65 is the smallest capacity in this range. Select it where the operating-pressure gas load fits 65 m³/h peak capacity and the smaller footprint suits the installation.
| Specification | Details |
|---|---|
| Maximum pumping speed | 65 m³/h without gas ballast; ±5%, C5 manual |
| Ultimate pressure | 0.01 mbar without gas ballast |
| Inlet / exhaust | G 2 in / G 1½ in |
| Electrical supply | Three-phase, version-specific: 200/400 V ±10% at 50 Hz; 230/460 V or 200/380 V ±10% at 60 Hz |
| Maximum current, 400 V / 50 Hz | 3.2 A; selected motor and protection must match |
| Water-vapour capacity with gas ballast | 1.9 kg/h; depends on installed configuration |
| Water-vapour tolerance with gas ballast | 60 mbar; installed configuration applies |
| Maximum discharge pressure above ambient | 200 mbar; higher backpressure worsens ultimate pressure |
| Dimensions (L × W × H) | 773 × 599 × 428 mm; standard envelope, check chosen connections |
| Mass | Approximately 105 kg |
| Cooling / ambient | Air-cooled; 0–40 °C |
Use the operating-pressure curve when sizing the pump. Peak speed alone does not establish evacuation time or continuous throughput. Gas ballast and exhaust backpressure affect performance.
For a UK 400 V, 50 Hz installation, specify the matching three-phase version. These are motor-terminal connections, with supply cable, isolation and motor protection selected for the installation. A domestic plug and mains lead are not assumed. Confirm the full order code, nameplate, phase sequence and starting arrangement.
Allow clear cooling airflow and space for belt and silencer service. Select inlet filtration and exhaust routing for the actual process. Above 1000 m installation altitude, request manufacturer review. An optional external variable-frequency drive must remain within the permitted motor speed; do not assume flow scales linearly with speed.
Gas ballast helps prevent condensation but changes attainable pressure. Water-vapour figures apply only to the stated configuration. Specify water load, cleaning procedures, particles and all process gases; the pump alone does not establish suitability for a complete food process or hazardous atmosphere.
VARODRY reaches a lower no-gas-ballast ultimate pressure than NOVADRY, but the required process pressure must still be assessed under load. Manual gas-ballast and purge-equipped builds need separate selection. Inlet and exhaust seal purge have different functions and require the correct gas supply and controls.
OEM, HD/O₂ and other special builds are distinct configurations. The standard ratings here do not certify oxygen service, ATEX operation or compatibility with corrosive gases. Provide the application for a specific configuration proposal.
These references identify specific builds for an enquiry. This model-level listing has no single manufacturer part number; confirm the selected build and current availability with Girovac.
| Specification | Details |
|---|---|
| Order code 111065V10 | 50 Hz, three-phase 200/400 V ±10% |
| Order code 111065V11 | 60 Hz, three-phase 230/460 V ±10% |
| Order code 111065V21 | 60 Hz, three-phase 200/380 V ±10% |


Specification source: 300766038_002_C5, technical data pages 13–14; installation and accessory sections. Match the document revision to the pump supplied.
Explore the VARODRY family guide or compare VARODRY 100, VARODRY 160, VARODRY 200. Return to the Leybold brand guide.
Compare NOVADRY for rough-vacuum duties. Assess required pressure under gas load before choosing a range.
For a VARODRY VD 65 quotation, send chamber volume, target pressure, gas and vapour composition, continuous throughput, pump-down time, cycle frequency, inlet and exhaust connections, electrical supply and quantity. Include control, filtration and installation-space requirements. Girovac will confirm the configuration, included equipment, price and delivery.
| Manufacturer | LEYBOLD |
|---|---|
| Equipment type | Dry Screw Vacuum Pumps |
| End / ultimate pressure | 0.01 mbar without gas ballast |
| Electrical supply | Three-phase, version-specific: 200/400 V ±10% at 50 Hz; 230/460 V or 200/380 V ±10% at 60 Hz |
| Maximum pumping speed | 65 m³/h without gas ballast; ±5%, C5 manual |
| Ordering options | 13 manufacturer codes — see configuration table |
| Inlet / exhaust | G 2 in / G 1½ in |
| Maximum current, 400 V / 50 Hz | 3.2 A; selected motor and protection must match |
| Water-vapour capacity with gas ballast | 1.9 kg/h; depends on installed configuration |
| Water-vapour tolerance with gas ballast | 60 mbar; installed configuration applies |
| Maximum discharge pressure above ambient | 200 mbar; higher backpressure worsens ultimate pressure |
| Dimensions (L × W × H) | 773 × 599 × 428 mm; standard envelope, check chosen connections |
| Mass | Approximately 105 kg |
| Cooling / ambient | Air-cooled; 0–40 °C |
Send the pump model and part number when asking about a replacement. Compatibility depends on the equipment and operating conditions.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
What to check in your quotation · Delivery · Returns and faults
Leybold VARODRY VD 65 Dry Screw Vacuum Pump
Prefer to talk? 01692 660 117 · [email protected]
We use your details to respond to your enquiry. Read our privacy policy.

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD
Compare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino