Home / High Vacuum Pumps / Single Stage Rotary PumpsGirovac equipment catalogue
Single Stage Rotary Pumps Browse single-stage rotary vacuum pumps and compare the listed models. Pumping speed, ultimate pressure and suitability for continuous operation depend on the individual pump and application.
Showing 1–12 of 19 results
DVP
Nominal pumping capacity 8.5 / 10.2 m³/h (50 / 60 Hz)
End / ultimate pressure 0.1 mbar — absolute
Motor power 0.37 kW (single- or three-phase) Compare View specifications → DVP
Nominal pumping capacity 4.3 / 5 m³/h (50 / 60 Hz)
End / ultimate pressure 0.1 mbar — absolute
Motor power 0.37 kW (single- or three-phase) Compare View specifications → DVP
Nominal pumping capacity 50 / 60 m³/h (50 / 60 Hz)
End / ultimate pressure 0.05 mbar — absolute
Motor power 1.1 / 1.35 kW (50 / 60 Hz; three-phase) Compare View specifications → MIL'S
Nominal pumping capacity 68 / 100 / 200 / 300 m³/h at 50 Hz for E65 / E100 / E200 / E300 respectively
End / ultimate pressure ≤ 0.06 mbar at 50 Hz; ATEX HV with gas ballast closed / without gas ballast
Lubricant MV99S synthetic for the specified ATEX configuration; confirm application-specific requirements Compare View specifications → DVP
The GVPSV4 is an oil-lubricated single-stage rotary vane vacuum pump for air-conditioning, refrigeration and laboratory applications. Nominal pumping speed is 4 m³/h at 50 Hz.
View specifications → DVP
Motor power 0.37 kW
Pumping technology Single-stage oil-sealed rotary vane
Nominal capacity (50 / 60 Hz) 8.5 / 10.2 m³/h Compare View specifications → MIL'S
Nominal pumping capacity 30 m³/h at 50 Hz; 35.3 m³/h at 60 Hz
PNEUROP pumping speed (50 Hz) 28 m³/h; PNEUROP 6602 at 20 °C
End / ultimate pressure HV: ≤ 0.5 mbar at 50 Hz; ≤ 0.5 mbar at 60 Hz; without gas ballast Compare View specifications → MIL'S
Nominal pumping capacity 28 m³/h at 50 Hz; 33 m³/h at 60 Hz
PNEUROP pumping speed (50 Hz) 26 m³/h; PNEUROP 6602 at 20 °C
End / ultimate pressure Standard: ≤ 2 mbar at 50/60 Hz; HV: ≤ 0.06 mbar at 50 Hz; ≤ 0.08 mbar at 60 Hz; without gas ballast Compare View specifications → MIL'S
Nominal pumping capacity 47.7 m³/h at 50 Hz; 57.2 m³/h at 60 Hz
PNEUROP pumping speed (50 Hz) 41.5 m³/h; PNEUROP 6602 at 20 °C
End / ultimate pressure HV: ≤ 0.5 mbar at 50 Hz; ≤ 0.5 mbar at 60 Hz; without gas ballast Compare View specifications → MIL'S
Nominal pumping capacity 44 m³/h at 50 Hz; 53 m³/h at 60 Hz
PNEUROP pumping speed (50 Hz) 42 m³/h; PNEUROP 6602 at 20 °C
End / ultimate pressure Standard: ≤ 2 mbar at 50/60 Hz; HV: ≤ 0.06 mbar at 50 Hz; ≤ 0.06 mbar at 60 Hz; without gas ballast Compare View specifications → MIL'S
Nominal pumping capacity 68 m³/h at 50 Hz; 81.6 m³/h at 60 Hz
PNEUROP pumping speed (50 Hz) 65 m³/h; PNEUROP 6602 at 20 °C
End / ultimate pressure Standard: ≤ 3 mbar at 50/60 Hz; HV: ≤ 0.06 mbar at 50 Hz; ≤ 0.06 mbar at 60 Hz; without gas ballast Compare View specifications → MIL'S
Nominal pumping capacity 100 m³/h at 50 Hz; 120 m³/h at 60 Hz
PNEUROP pumping speed (50 Hz) 96 m³/h; PNEUROP 6602 at 20 °C
End / ultimate pressure Standard: ≤ 3 mbar at 50/60 Hz; HV: ≤ 0.06 mbar at 50 Hz; ≤ 0.06 mbar at 60 Hz; without gas ballast Compare View specifications → Help choosing single-stage rotary pumps For help selecting equipment, tell us the process, duty cycle, electrical supply and required pressure. If you are replacing a pump, include its make, model and connection details.
Discuss your requirements with Girovac or call 01692 660 117 .
Explore brand-specific ranges Use a family guide to compare models and understand the range before selecting a product.
Need help choosing equipment? Send the operating requirements and process details. For a replacement, include the existing model and connection.