LEYBOLD
Leybold ECODRY 25 plus Dry Multistage Roots Vacuum Pump
- Electrical supply
- Single-phase 100–127 or 200–240 V AC ±10%, 50/60 Hz
- Maximum pumping speed
- 25 m³/h at standard ambient temperature and pressure
- Typical ultimate pressure
- 0.01 mbar
The ECODRY 65 plus is an air-cooled dry multistage Roots pump for clean-gas laboratory vacuum, analytical equipment and turbomolecular backing. Maximum air pumping speed is 55 m³/h without gas ballast, with an ultimate pressure below 0.03 mbar under the same gas-ballast condition.
Leybold ECODRY 40/65 plus manufacturer range photograph; standard gas-ballast version shown. The 65 He plus has a different gas-ballast arrangement.
Part of the Leybold ECODRY plus dry multistage roots pumps family. Compare the range and other model options.
Tell us the configuration and quantity you need. Include your process requirements if you would like help with selection.
View quote listThe ECODRY 65 plus is an air-cooled dry multistage Roots pump for clean-gas laboratory vacuum, analytical equipment and turbomolecular backing. Maximum air pumping speed is 55 m³/h without gas ballast, with an ultimate pressure below 0.03 mbar under the same gas-ballast condition.
Choose the 65 plus for 55 m³/h air capacity and a DN40 inlet. The model name is not its air pumping-speed rating. For helium recovery where total leak tightness matters, compare the separate 65 He plus.
| Specification | Details |
|---|---|
| Maximum pumping speed | 55 m³/h on air, without gas ballast; ±5% |
| Ultimate pressure | <0.03 mbar without gas ballast |
| Inlet / exhaust | DN40 ISO-KF / DN16 ISO-KF |
| Electrical supply | Single-phase 100–120 V or 200–240 V ±10%, 50/60 Hz; separate order codes |
| Rated power / current | 1200 W; 15 A low-voltage version / 10 A high-voltage version |
| Dimensions (L × W × H) | 623 × 320 × 298 mm; allow additional connection and cooling clearance |
| Mass | Approximately 43 kg, ±1 kg |
| Cooling / ambient | Air-cooled; 5–40 °C |
| Gas ballast | <0.1 mbar ultimate pressure with gas ballast; 20 mbar water-vapour tolerance |
| Water-vapour capacity with gas ballast | 500 g/h |
Pressure and speed refer to the pump, not guaranteed chamber performance. The 40/65 platform has different pressure, connection and electrical ratings from ECODRY 25/35 plus.
For a UK 230 V installation, specify the 200–240 V version. The mains cable is ordered separately: Leybold lists 161810UK, BS1363 to IEC C19, 2 m. The pump has an IEC C20 inlet; confirm circuit protection and the selected nameplate rating.
The manual lists two centring rings, two clamping rings, two blank flanges and the D-sub 9-pin bridge connector for manual operation in the supplied equipment. Interface cables, inlet screens and mounting accessories require separate selection.
The standard 40/65 plus pumps suit clean, dry, particle-free gases and water vapour within their gas-ballast limits. Give the full gas composition before selecting a pump for solvents or aggressive gases. Gas ballast improves vapour handling but raises ultimate pressure.
Local start/stop, the X1 control interface and the X104 RS485 interface support equipment integration. Specify the intended control method and cables. The dry pumping chamber has no process oil; bearings and gears use PFPE lubrication.
The manual excludes short-cycle pumping with high repetition rates. Above 2000 m installation altitude, inlet pressure should not permanently exceed 50 mbar. Allow unobstructed cooling airflow and service access.
These references identify specific builds for an enquiry. This model-level listing has no single manufacturer part number; confirm the selected build and current availability with Girovac.
| Specification | Details |
|---|---|
| Order code 161065V21 | 100–120 V ±10%, 1-phase, 50/60 Hz |
| Order code 161065V22 | 200–240 V ±10%, 1-phase, 50/60 Hz |


Specification source: 300758785_002_C3, January 2026, pages 12–15, 17–22 and 37; 3610 0161 02, February 2026. Match the document revision to the pump supplied.
Explore the ECODRY plus family guide or compare ECODRY 40, ECODRY 65 he. Return to the Leybold brand guide.
For turbo backing, compare the TURBOVAC i / iX range. A standalone backing pump does not imply compatibility with a preconfigured TURBOLAB station.
For an ECODRY 65 plus quotation, send chamber volume, target pressure, gas and vapour composition, continuous throughput, pump-down time, cycle frequency, inlet and exhaust connections, electrical supply and quantity. Include control, filtration and installation-space requirements. Girovac will confirm the configuration, included equipment, price and delivery.
| Manufacturer | LEYBOLD |
|---|---|
| Equipment type | Dry Multistage Roots Vacuum Pumps |
| End / ultimate pressure | <0.03 mbar without gas ballast |
| Electrical supply | Single-phase 100–120 V or 200–240 V ±10%, 50/60 Hz; separate order codes |
| Maximum pumping speed | 55 m³/h on air, without gas ballast; ±5% |
| Inlet / exhaust | DN40 ISO-KF / DN16 ISO-KF |
| Rated power / current | 1200 W; 15 A low-voltage version / 10 A high-voltage version |
| Dimensions (L × W × H) | 623 × 320 × 298 mm; allow additional connection and cooling clearance |
| Mass | Approximately 43 kg, ±1 kg |
| Cooling / ambient | Air-cooled; 5–40 °C |
| Gas ballast | <0.1 mbar ultimate pressure with gas ballast; 20 mbar water-vapour tolerance |
| Water-vapour capacity with gas ballast | 500 g/h |
Send the pump model and part number when asking about a replacement. Compatibility depends on the equipment and operating conditions.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
What to check in your quotation · Delivery · Returns and faults
Leybold ECODRY 65 plus Dry Multistage Roots Vacuum Pump
Prefer to talk? 01692 660 117 · [email protected]
We use your details to respond to your enquiry. Read our privacy policy.

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD
Compare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino