DVP
DVP LC 25 Lubricated Rotary Vane Vacuum Pump
- Nominal pumping capacity
- 25 m³/h (50 Hz) / 29 m³/h (60 Hz)
- End / ultimate pressure
- 0.5 mbar (abs)
- Motor power
- 0.75 kW
DVP LC 61WR water-resistant rotary vane vacuum pump — 60 m³/h water-resistant rotary vane pump with IE3 motor. UK supply, genuine spares & servicing from Girovac. Price on application.
Part of the DVP LC WR water-resistant pumps family. Compare the range and other model options.
Tell us the configuration and quantity you need. Include your process requirements if you would like help with selection.
View quote listThe DVP LC 61WR is a single-stage, oil-lubricated rotary vane vacuum pump built for wet duty from DVP Vacuum Technology. It pumps 60 m³/h and reaches an ultimate pressure of 4 mbar absolute. Girovac supplies the LC 61WR in the UK, stocks genuine DVP spares and oil, and services DVP pumps in-house. Price on application.
| Pumping speed | 60 m³/h (50 Hz) / 72 m³/h (60 Hz) |
|---|---|
| Ultimate pressure | 4 mbar |
| Motor power | 1.5 kW (three-phase, IE3) at 50 Hz |
| Weight | 45 kg |
| Oil type | DVP SW60 |
| Price | On application |
The LC 61WR is part of DVP’s LC-WR water-resistant range — 60 m³/h water-resistant rotary vane pump with IE3 motor. Oil-sealed rotary vane pumps like this one are the workhorses of industrial vacuum: the oil seals the clearances, lubricates the vanes and carries away heat, which is what lets a single-stage rotary vane pump hold a steady working vacuum under continuous duty.
The WR models share the LC body but add a device that separates water condensate from the oil and expels it once the pump stops. That is what lets them run in air streams carrying far more water vapour than a standard pump could tolerate — and it is also why their ultimate pressure is higher. Choose a WR pump for wet duty, not for deep vacuum.
DVP’s datasheet for the LC 61WR does not list specific applications. Pumps in DVP’s LC-WR water-resistant range are used across vacuum packaging, handling and lifting, printing, laboratory and general industrial vacuum duties. If you tell us the process, volume and target pressure, we will confirm whether the LC 61WR is the right choice.
| Nominal capacity (pumping speed) | 60 m³/h (50 Hz) / 72 m³/h (60 Hz) |
|---|---|
| Ultimate pressure (absolute) | 4 mbar |
| Continuous-duty working range | 400 to 4 mbar (abs) |
| Max. inlet pressure for water vapour | 50 mbar |
| Max. water-vapour pumping rate | 2.4 kg/h |
| Maximum inlet air temperature | 40 °C |
| Motor power | 1.5 kW (three-phase, IE3) at 50 Hz |
| Nominal speed | 1400 rpm (50 Hz) / 1700 rpm (60 Hz) |
| Noise level (UNI EN ISO 2151, K 3 dB) | 66 dB(A) at 50 Hz / 68 dB(A) at 60 Hz |
| Weight | 45 kg |
| Oil type | DVP SW60 |
| Oil quantity | 1.5–2 dm³ |
| Pump type | Single-stage, oil-lubricated rotary vane (water-resistant) |
| DVP part number | 9690044 |
| Manufacturer | DVP Vacuum Technology |
Figures are taken from DVP’s published datasheet for the LC 61WR (part number 9690044). Noise is measured to UNI EN ISO 2151. Need the pumping speed at your actual working pressure rather than the nominal figure? Ask us for the curve.
The closest alternatives by pumping speed are the DVP LC 40WR and DVP LC 60WR. If you are between sizes, size on the volume to be evacuated and the time you have to do it in, not on the nominal figure alone.
| DVP LC 61WR (this pump) | 60 m³/h (50 Hz) / 72 m³/h (60 Hz) · ultimate 4 mbar |
|---|---|
| DVP LC 40WR | 40 m³/h (50 Hz) / 48 m³/h (60 Hz) · ultimate 4 mbar |
| DVP LC 60WR | 60 m³/h (50 Hz) / 72 m³/h (60 Hz) · ultimate 4 mbar |
See the full DVP pump range or read our guide to the types of vacuum pump.
Established in 1983, with more than 40 years in the industrial vacuum sector, Girovac supplies, services and stocks spares for DVP vacuum pumps from our workshop in North Walsham, Norfolk. We can supply the LC 61WR new, source genuine DVP spares, and repair, service or recondition DVP pumps.
Routine care is straightforward: keep the oil clean and topped up, change it on schedule, and keep the inlet filter clear. Most cases of a not reaching ultimate vacuum come down to tired oil or a leak rather than a worn pump. See our DVP vacuum pump service guide for the full routine.
We do not list prices online. Every LC 61WR is quoted to your application, duty cycle and phase requirement, including delivery to anywhere in the UK. Contact us for a quote on price, availability and technical advice.
The LC 61WR reaches an ultimate pressure of 4 mbar absolute, operating continuously across 400 to 4 mbar (abs), with a nominal pumping speed of 60 m³/h (50 Hz) / 72 m³/h (60 Hz).
The LC 61WR uses DVP SW60 rotary vane pump oil, with a charge of 1.5–2 dm³. Change it when it darkens or the achievable vacuum drops off. Girovac stocks genuine DVP oil.
The LC 61WR is a single-stage, oil-lubricated (oil-sealed) rotary vane vacuum pump. Single-stage pumps of this type typically reach the 10⁻¹ mbar region; for deeper vacuum you would need a two-stage pump.
The LC 61WR is rated at 1.5 kW (three-phase, IE3) at 50 Hz and weighs 45 kg. Tell us whether you need single-phase or three-phase when you enquire.
Girovac quotes the LC 61WR on application rather than listing a price, because cost depends on phase, accessories and delivery. Contact us and we will come back with a firm price and lead time.
Yes. Established in 1983, with more than 40 years in the industrial vacuum sector, Girovac supplies, services and stocks spares for DVP vacuum pumps from our workshop in North Walsham, Norfolk. We service, repair and recondition DVP pumps including the LC 61WR, and stock genuine spares.
Download the original DVP LC 61WR manufacturer datasheet (PDF). Check the model columns, supply frequency and operating conditions before comparing values.
Depending on the duty, compare DVP LC 106WR, DVP LC 151WR, DVP CPV liquid-separator systems. These are different configurations, not automatic replacements. Check working pressure, flow, gas load and installation requirements. Browse the complete DVP range for more options.
For rough-vacuum duties, review industrial vacuum dial gauges; for pump-down measurement into lower pressures, compare Pirani vacuum transducers. Match the instrument range and gas compatibility to the operating pressure. We can also quote vacuum gauge calibration at the relevant test points.
Send the required pressure, simultaneous demand and control requirements when discussing industrial vacuum systems. Consider pumps, pipework, filtration and instrumentation together.
| Manufacturer | DVP |
|---|---|
| Equipment type | Single Stage Oil Filled Pumps |
| Nominal pumping capacity | 60 m³/h (50 Hz) / 72 m³/h (60 Hz) |
| End / ultimate pressure | 4 mbar — absolute |
| Motor power | 1.5 kW (three-phase, IE3) at 50 Hz |
| Lubricant | DVP SW60 |
| Noise level | 66 dB(A) at 50 Hz / 68 dB(A) at 60 Hz — UNI EN ISO 2151, K 3 dB |
| Weight | 45 kg |
| DVP part number | 9690044 |
Send the pump model and part number when asking about a replacement. Compatibility depends on the equipment and operating conditions.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
What to check in your quotation · Delivery · Returns and faults
DVP LC 61WR Water-Resistant Rotary Vane Vacuum Pump
Prefer to talk? 01692 660 117 · [email protected]
We use your details to respond to your enquiry. Read our privacy policy.

DVP

DVP

DVP

MIL'S
Compare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino