Digital Pirani Vacuum Transducers
- Measurement principle
- Pirani; gas-dependent
- Measuring range
- 1000 to 1 × 10⁻⁴ mbar
- Pressure reference
- Absolute
Vacuum transducers for compatible PLC inputs and display units. Piezo, capacitance and Pirani sensing options let you select the measurement principle for the process.
Shown: Thyracont VSP63MV analogue Pirani vacuum transducer. Select the model, sensor, connection and interface required for the application.
Tell us the configuration and quantity you need. Include your process requirements if you would like help with selection.
View quote listVacuum transducers for compatible PLC inputs and display units. Piezo, capacitance and Pirani sensing options let you select the measurement principle for the process.
Send the input type, supply and scaling used by your controller. A matching signal range alone does not prove compatibility: the pressure transfer function, pinout and measurement range must also agree.
No. Two instruments can use the same voltage span with different pressure scaling. Check the transfer function and controller configuration before replacement.
Yes. Tell us the operating range, required test points and certificate requirement. We will confirm the calibration option for the selected instrument before quoting. Discuss vacuum gauge calibration.
Compare vacuum gauge controllers and portable meters and data loggers. Check the pressure reference, measurement range and output rather than selecting by connection alone.
Explore measurement and control requirements for the INDUSVAC centralised vacuum system and LABOVAC laboratory vacuum system. Check existing sensors, controller inputs, switching duties and connection details before selecting an additional or replacement instrument.
Send the pressure range and reference (absolute or relative), process gas, connection, quantity and required delivery date. Include the existing model or a photograph for replacement enquiries.
Compare vacuum gauge types or enquire about this instrument.
For named Leybold transmitters, compare TTR 91 RN, TTR 96 RN, TTR 97 RN, PTR 90 RN and PTR 225 RN and CERAVAC CTR 101. Pirani and ionisation readings depend on gas type; capacitance diaphragm measurement is gas-independent. Confirm the exact transfer function, supply, pinout and full-scale range.
See the Thyracont VSP63D and VSR53D for named models offering both 0–10 V and RS485. Match the supply, pinout and signal scaling to the receiving controller.
| Equipment type | Vacuum gauges & instrumentation |
|---|---|
| Pressure reference | Absolute |
| Piezo option | 1400–1 mbar |
| Pirani option | 1000–0.0001 mbar |
| Chemical-service Pirani option | 1000–0.0005 mbar; compatibility subject to media review |
| Output options | 4–20 mA or 0–10 V, model-dependent |
| Integration | Linear or logarithmic transfer function, model-dependent |
Send the gauge model, pressure range and process details for calibration, replacement or compatibility advice.
Confirm the range, pressure reference, connection, electrical output and whether cables, a controller or calibration are included.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
What to check in your quotation · Delivery · Returns and faults
Analogue Vacuum Transducers
Prefer to talk? 01692 660 117 · [email protected]
We use your details to respond to your enquiry. Read our privacy policy.



LEYBOLD

LEYBOLD
Compare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino