EDWARDS
Edwards ADC Active Digital Controller
- Gauge channels
- Standard: one; MkII Enhanced: two
- Supply
- 100–240 V AC, 47–63 Hz
- Display
- mbar, Torr, Pa or volts
EDWARDS brand guide / Product family
Compare Edwards instrument, turbo and active-gauge controllers, channel counts, power budgets and compatible interfaces.
| Specification | Details |
|---|---|
| Edwards TIC Instrument Controller | 3 or 6, depending on version |
| Edwards TIC Turbo and Instrument Controller | 100 W or 200 W |
| Edwards ADC Active Digital Controller | Standard: one; MkII Enhanced: two |
| Edwards TAG Turbo and Active Gauge Controller | One compatible active gauge |
TIC Instrument controllers offer three or six gauge channels; TIC Turbo and Instrument controllers combine compatible pump and gauge control in 100 W or 200 W versions. Standard ADC supports one compatible APG or WRG gauge; MkII Enhanced adds channels, interfaces and supported gauge types. TAG controls a compatible turbo and one active gauge using a separately selected 24 V supply. Match exact gauge interfaces and pump loads before ordering.
Each product page provides documented choices, technical conditions, manufacturer imagery and downloads. Confirm process compatibility, connections, controls, electrical supply and included accessories as a complete configuration. Prices and delivery remain enquiry-based.
Compare active gauges, nEXT pumps. Explore the Edwards brand guide for the wider catalogue.
Send working pressure, required flow or chamber volume, gas and vapour load, duty cycle, available utilities and existing equipment references. For measurement, include gas species, accuracy requirement, controller and interface.
Compare values with their stated gas, frequency and configuration conditions. A blank specification means it needs confirmation. Listed equipment is subject to a quotation; inclusion here does not indicate stock.
| Model | Gauge channels | Supply | Display | Turbo output |
|---|---|---|---|---|
| Edwards ADC Active Digital Controller | Standard: one; MkII Enhanced: two | 100–240 V AC, 47–63 Hz | mbar, Torr, Pa or volts | Confirm for this model |
| Edwards TAG Turbo and Active Gauge Controller | One compatible active gauge | 24 V DC; external power supply selected separately | Confirm for this model | 24 V DC, 160 W maximum |
| Edwards TIC Instrument Controller | 3 or 6, depending on version | 100–240 V AC, 50/60 Hz | Confirm for this model | Confirm for this model |
| Edwards TIC Turbo and Instrument Controller | Confirm for this model | 90–264 V AC, 47–63 Hz | Confirm for this model | Confirm for this model |

EDWARDS

EDWARDS

EDWARDS

EDWARDS
Open the model page for its specifications and available manufacturer downloads. Match the full model, suffix and revision to the equipment being supplied. Keep installation limits and performance test conditions with the figure when comparing alternatives.
Return to the EDWARDS brand guide · Explore all product families
Send the process, working pressure, gas, required capacity and electrical supply. For measurement, include the range, connection, output and controller. We can confirm the model, accessories and documentation for your quotation.
Compare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino