Leybold TURBOLAB 850 Turbomolecular Pumping Station
- End / ultimate pressure
- <3 × 10⁻⁸ mbar (ISO); <3 × 10⁻¹⁰ mbar (CF), subject to system conditions
- Weight
- 106–130 kg by configuration
- High-vacuum inlet connection
- DN160 ISO-K or CF
The Edwards T-Station 85 combines an nEXT85 turbomolecular pump, backing pump and integrated control in a compact high-vacuum station. Choose dry scroll, dry diaphragm or oil-sealed backing and the inlet flange around the chamber and process.
Manufacturer illustration: Edwards T-Station 85 with mXDS3s backing pump. Confirm the selected configuration and supplied equipment in the quotation.
Part of the Edwards T-Station turbomolecular pumping stations family. Compare the range and other model options.
Tell us the configuration and quantity you need. Include your process requirements if you would like help with selection.
View quote listThe Edwards T-Station 85 combines an nEXT85 turbomolecular pump, backing pump and integrated control in a compact high-vacuum station. Choose dry scroll, dry diaphragm or oil-sealed backing and the inlet flange around the chamber and process.
| Specification | Details |
|---|---|
| Nitrogen pumping speed | 47 l/s NW40; 84 l/s ISO63 or CF63 |
| Inlet options | NW40 / ISO63 / CF63 |
| Backing pumps | mXDS3s, XDD1 or E2M1.5 |
| Backing speed at 50 Hz | mXDS3s 3; XDD1 1.2; E2M1.5 1.6 m³/h |
| Maximum mass by backing pump | 19 / 18 / 21 kg, mXDS3s / XDD1 / E2M1.5 |
| Ambient operation | Dry versions 5–40 °C; oil-sealed versions 12–40 °C |
| Specification | Details |
|---|---|
| TS85M1003 | NW40, mXDS3s dry scroll backing, 230 V |
| TS85M1006 | NW40, mXDS3s dry scroll backing, 115 V |
| TS85M2003 | ISO63, mXDS3s dry scroll backing, 230 V |
| TS85M2006 | ISO63, mXDS3s dry scroll backing, 115 V |
| TS85M3003 | CF63, mXDS3s dry scroll backing, 230 V |
| TS85M3006 | CF63, mXDS3s dry scroll backing, 115 V |
| TS85D1001 | NW40, XDD1 dry diaphragm backing, 200–230 V |
| TS85D1002 | NW40, XDD1 dry diaphragm backing, 100–120 V |
| TS85D2001 | ISO63, XDD1 dry diaphragm backing, 200–230 V |
| TS85D2002 | ISO63, XDD1 dry diaphragm backing, 100–120 V |
| TS85D3001 | CF63, XDD1 dry diaphragm backing, 200–230 V |
| TS85D3002 | CF63, XDD1 dry diaphragm backing, 100–120 V |
| TS85W1001 | NW40, E2M1.5 oil-sealed backing, 200–230 V |
| TS85W1002 | NW40, E2M1.5 oil-sealed backing, 100–120 V |
| TS85W2001 | ISO63, E2M1.5 oil-sealed backing, 200–230 V |
| TS85W2002 | ISO63, E2M1.5 oil-sealed backing, 100–120 V |
| TS85W3001 | CF63, E2M1.5 oil-sealed backing, 200–230 V |
| TS85W3002 | CF63, E2M1.5 oil-sealed backing, 100–120 V |
The mXDS3s option offers dry scroll compression with an inlet isolation valve and exhaust filter. XDD1 uses a dry diaphragm backing pump. E2M1.5 uses sealing oil and requires oil and exhaust-mist management. Select the complete station around gas compatibility and required pump-down time, not turbo speed alone.
Attainable pressure depends on flange, seals, backing pump, bakeout and the connected chamber. Use the selected station’s manufacturer specification when setting an acceptance pressure. Integrated control provides coordinated operation; a gauge connection does not mean a gauge is included. Select the compatible active gauge, cable and vent valve explicitly.
Choose the listed 230 V or 200–230 V build for the appropriate UK supply and specify UK mains lead A50505000 separately. Vent valves, active gauges, gauge cables and the E2M1.5 mist filter appear as separate accessories. The drawing shows multiple backing-pump arrangements; confirm the final footprint and clearance.
Send chamber volume, target pressure, gas load, inlet flange, backing preference and power supply. Compare standalone nEXT pumps and Edwards active gauges.

Source: 3601-0254-01-T-Station-85-Datasheet, supplied from the manufacturer’s official website. This model-level listing retains configuration choices; the exact order reference, included equipment and lead time are confirmed in the quotation.
Explore the T-Station range and Edwards brand guide. Compare vacuum gauges and controllers, plan gauge calibration, or discuss servicing.
For T-Station 85 Turbomolecular Pumping Station, include working pressure, required flow or chamber volume, gas and vapour load, operating hours, electrical supply and connections. For a replacement, send the complete nameplate and serial number so the configuration can be checked.
| Manufacturer | EDWARDS |
|---|---|
| Equipment type | High Vacuum Pumping Stations |
| Nitrogen pumping speed | 47 l/s NW40; 84 l/s ISO63 or CF63 |
| Inlet options | NW40 / ISO63 / CF63 |
| Backing pumps | mXDS3s, XDD1 or E2M1.5 |
| Backing speed at 50 Hz | mXDS3s 3; XDD1 1.2; E2M1.5 1.6 m³/h |
| Maximum mass by backing pump | 19 / 18 / 21 kg, mXDS3s / XDD1 / E2M1.5 |
| Ambient operation | Dry versions 5–40 °C; oil-sealed versions 12–40 °C |
Send the pump model and part number when asking about a replacement. Compatibility depends on the equipment and operating conditions.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
What to check in your quotation · Delivery · Returns and faults
Edwards T-Station 85 Turbomolecular Pumping Station
Prefer to talk? 01692 660 117 · [email protected]
We use your details to respond to your enquiry. Read our privacy policy.

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD
Compare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino