EDWARDS
Edwards nXDS6i Dry Scroll Vacuum Pump
- Electrical supply
- Single-phase 100–127 V ±10% or 200–240 V ±10%, 50–60 Hz
- Peak pumping speed
- 6.2 m³/h
- Ultimate pressure, gas ballast 0
- 0.02 mbar
The SCROLLVAC 15 plus is an oil-free scroll pump for laboratory vacuum, analytical equipment and suitable turbomolecular backing duties. Peak speed 14.5 m³/h (1-phase 50/60 Hz or 3-phase 60 Hz); 12.6 m³/h at 3-phase 50 Hz.
Manufacturer range photograph: SCROLLVAC 15 plus, single-phase version, illustrating the 7–18 plus range. The supplied model and motor variant are confirmed on the quotation.
Part of the Leybold SCROLLVAC plus dry scroll pumps family. Compare the range and other model options.
Tell us the configuration and quantity you need. Include your process requirements if you would like help with selection.
View quote listThe SCROLLVAC 15 plus is an oil-free scroll pump for laboratory vacuum, analytical equipment and suitable turbomolecular backing duties. It delivers a peak pumping speed of 14.5 m³/h with a single-phase supply at 50/60 Hz or a three-phase supply at 60 Hz. Select the motor and gas-handling variant around the application rather than the model number alone.
The 15 plus increases peak speed to 14.5 m³/h while retaining the 0.009 mbar ultimate-pressure rating under the stated single-phase/60 Hz conditions. Its recommended chamber volume is 75 litres.
| Specification | Details |
|---|---|
| Peak speed: 1-phase 50/60 Hz or 3-phase 60 Hz | 14.5 m³/h |
| Peak speed: 3-phase 50 Hz | 12.6 m³/h |
| Ultimate pressure, gas ballast closed | 0.009 mbar: 1-phase 50/60 Hz or 3-phase 60 Hz; 0.04 mbar: 3-phase 50 Hz |
| Maximum continuous inlet pressure | 200 mbar |
| Recommended chamber volume from atmosphere | 75 litres; see duty limitations below |
| Inlet / exhaust | DN25 ISO-KF / DN25 ISO-KF |
| Dimensions (L × W × H) | 430 × 282 × 325 mm |
| Mass | 26 kg |
| Ambient operation | 5–40 °C; non-condensing |
Pressure values above are for gas ballast position 0. Both pumping speed and ultimate pressure change for three-phase 50 Hz operation; do not use the single-phase figures for that configuration.
Single-phase: 100–127 or 200–240 V AC ±10%, 50/60 Hz. For a UK 230 V installation, specify the 200–240 V setting and the 2 m 161810UK BS1363/IEC C19 mains-cable accessory. The single-phase version has an integrated frequency converter, local controls and a remote-control interface.
Three-phase: 200 V ±10% or 380–415 V +6%/−10% at 50 Hz; 200–230 V ±10% or 460 V ±10% at 60 Hz. The UK 400 V three-phase choice uses the lower 50 Hz pumping-speed figures above. Electrical connection and motor protection must match the selected variant.
Standard: adjustable gas ballast. H: a blank adapter replaces the gas-ballast control to prevent accidental opening, useful for suitable gas-recovery duties. C: a variant to assess for applications involving corrosive substances; suitability requires the actual gas composition and operating conditions. Some documented order codes are available on request only.
These pumps can evacuate from atmosphere, but prolonged operation above the continuous inlet-pressure limit can shorten bearing and tip-seal life. Larger chambers may be possible after review. The manual describes the range as optimised for constant throughput and not recommended for cyclic duty.
Opening gas ballast increases attainable pressure and changes vapour handling. Specify vapour load, duty cycle and exhaust conditions. Available accessories include a silencer, vibration isolators and gas-ballast adapters. Tip seals are service items. Accessories and control cables should be listed explicitly on the quotation.


Leybold operating instructions (PDF) — 300668736_002_C9, April 2026, pages 21–29, 31–41 and 48–49. Consult the full instructions for operating limits, electrical installation and maintenance.
Compare SCROLLVAC 7 plus, SCROLLVAC 10 plus, SCROLLVAC 18 plus. Browse the Leybold catalogue.
To request a quotation for the SCROLLVAC 15 plus Dry Scroll Vacuum Pump, send chamber volume, target pressure, gas and vapour composition, throughput, pump-down time and cycle frequency, connection size, electrical supply and quantity. Include any control, exhaust-treatment and installation-space requirements. Girovac will confirm the suitable configuration, price and delivery.
| Manufacturer | LEYBOLD |
|---|---|
| Equipment type | Dry Scroll Vacuum Pumps |
| Peak speed: 1-phase 50/60 Hz or 3-phase 60 Hz | 14.5 m³/h |
| Peak speed: 3-phase 50 Hz | 12.6 m³/h |
| Ultimate pressure, gas ballast closed | 0.009 mbar: 1-phase 50/60 Hz or 3-phase 60 Hz; 0.04 mbar: 3-phase 50 Hz |
| Maximum continuous inlet pressure | 200 mbar |
| Recommended chamber volume from atmosphere | 75 litres; see duty limitations below |
| Inlet / exhaust | DN25 ISO-KF / DN25 ISO-KF |
| Dimensions (L × W × H) | 430 × 282 × 325 mm |
| Mass | 26 kg |
| Ambient operation | 5–40 °C; non-condensing |
Send the pump model and part number when asking about a replacement. Compatibility depends on the equipment and operating conditions.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
What to check in your quotation · Delivery · Returns and faults
Leybold SCROLLVAC 15 plus Dry Scroll Vacuum Pump
Prefer to talk? 01692 660 117 · [email protected]
We use your details to respond to your enquiry. Read our privacy policy.

EDWARDS

EDWARDS

EDWARDS

LEYBOLD
Compare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.