The Edwards mXDS3s is a compact dry scroll vacuum pump for laboratory equipment, small vacuum systems and suitable turbomolecular backing duties. The scientific version includes an inlet valve with delayed opening and an exhaust silencer.
Manufacturer illustration: Edwards mXDS3s with inlet isolation valve. Confirm the selected configuration and supplied equipment in the quotation.
The Edwards mXDS3s is a compact dry scroll vacuum pump for laboratory equipment, small vacuum systems and suitable turbomolecular backing duties. The scientific version includes an inlet valve with delayed opening and an exhaust silencer.
Key specifications
Specification
Details
Maximum pumping speed, 50 / 60 Hz
3 / 3.5 m³/h
Ultimate pressure
0.1 mbar, gas ballast closed; 0.15 mbar, one turn open
Electrical supply
Voltage-specific 100, 115, 200 or 230 V single-phase; 50/60 Hz
Inlet
DN16 ISO-KF
Exhaust
1/8-inch BSP for 6 × 8 mm hose
Dimensions, L × W × H
224 × 158 × 231 mm
Mass
8 kg
Power at ultimate
210 W
Ambient operation
5–40 °C
Configuration choices
Specification
Details
mXDS3s 230 V
UK single-phase selection; exact order reference and mains lead confirmed with quotation
Other voltages
Separate 100, 115 and 200 V builds; do not assume universal-voltage operation
Duty and gas ballast
The pump can evacuate from atmospheric pressure, but prolonged high-inlet-pressure operation can reduce bearing life. Gas ballast helps with compatible vapour loads while increasing ultimate pressure. Exhaust to atmosphere within the manufacturer’s permitted conditions; excessive back pressure can shorten tip-seal life.
Installation and maintenance
Specify the matching mains lead, inlet connections and process protection. Keep ventilation clear and plan tip-seal service. Dry compression eliminates sealing oil in the vacuum chamber but does not remove maintenance requirements. The standard and scientific versions have the same nominal vacuum performance.
Original manufacturer technical reference for Edwards mXDS3s with inlet isolation valve. Use the drawing and dimensions for the selected configuration. Select to enlarge.
Source: 3601-0723-01-mXDS3-3s-datasheet, supplied from the manufacturer’s official website. This model-level listing retains configuration choices; the exact order reference, included equipment and lead time are confirmed in the quotation.
For mXDS3s Dry Scroll Vacuum Pump, include working pressure, required flow or chamber volume, gas and vapour load, operating hours, electrical supply and connections. For a replacement, send the complete nameplate and serial number so the configuration can be checked.
Specifications
Manufacturer
EDWARDS
Equipment type
Dry Scroll Vacuum Pumps
End / ultimate pressure
0.1 mbar, gas ballast closed; 0.15 mbar, one turn open
Electrical supply
Voltage-specific 100, 115, 200 or 230 V single-phase; 50/60 Hz
Maximum pumping speed, 50 / 60 Hz
3 / 3.5 m³/h
Inlet
DN16 ISO-KF
Exhaust
1/8-inch BSP for 6 × 8 mm hose
Dimensions, L × W × H
224 × 158 × 231 mm
Mass
8 kg
Power at ultimate
210 W
Ambient operation
5–40 °C
Parts, consumables and workshop support
Send the pump model and part number when asking about a replacement. Compatibility depends on the equipment and operating conditions.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.