Leybold TURBOVAC multi-inlet pumps provide separate vacuum connections for multi-chamber instruments in one compact pumping arrangement. Girovac can help specify the inlet layout, pressure and gas load at each stage, together with the backing pump, cooling and controls.
Some instruments need several vacuum stages within a limited space. TURBOVAC multi-inlet designs use a special rotor and two or more inlets to serve those stages from one pump assembly. This can reduce the number of separate pumps and connecting components in the instrument.
Leybold offers cartridge arrangements and customised housings or chamber integration. The design is selected around the instrument rather than a single headline pumping-speed figure.
Define the duty at each inlet
Selection detail
Information to provide
Vacuum stages
Number of chambers and required pressure at each connection
Gas load
Gas species and throughput at every inlet, including changes during operation
Connections
Flange sizes, port positions and available space
Integration
Complete housing or cartridge arrangement, mounting and service access
Supporting equipment
Backing pump, cooling, power supply and control requirements
Send a chamber drawing or vacuum schematic if you have one. We can use it to discuss the arrangement and confirm the pump configuration and manufacturer reference for your quotation.
Questions about multi-inlet turbomolecular pumps
Is a multi-inlet pump the same as a pump connected to a manifold?
No. A multi-inlet design has connections at different pumping stages. Their performance is part of the pump design, so the inlet positions and gas loads need to be specified together. Compare the wider TURBOVAC multi-inlet family when planning your arrangement.
Can I use a standard TURBOVAC pumping-speed figure for every inlet?
No. Ask for the performance of the selected configuration at each connection. Include the gas species and simultaneous loads so the assessment reflects your instrument’s operating conditions.
Does the system still need a backing pump?
Yes. Turbomolecular pumping requires a suitable backing-vacuum arrangement. Tell us about your existing equipment or ask us to include it in the specification. Our laboratory vacuum systems guide helps you plan the complete installation.
What if my instrument only has one vacuum chamber?
A standard single-inlet pump may be appropriate. Browse our turbomolecular pumps, or send your required pressure and gas load so we can help narrow the choice.
Discuss your instrument with Girovac
Add this product to your quote list or call 01692 660 117. For a replacement, include the complete pump reference and serial number; for a new design, include the chamber layout and operating requirements.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.