DVP
DVP LC 20 Lubricated Rotary Vane Vacuum Pump
- Nominal pumping capacity
- 20 m³/h (50 Hz) / 24 m³/h (60 Hz)
- End / ultimate pressure
- 2 mbar — absolute
- Motor power
- 0.75 kW (single-phase) / 0.75 kW (three-phase) at 50 Hz
DVP LC 41 single-stage rotary vane vacuum pump — 40 m³/h, ultimate 0.1 mbar, selectable gas ballast. UK supply, genuine spares & servicing from Girovac. Price on application.
Part of the DVP LC & MD oil-lubricated pumps family. Compare the range and other model options.
Tell us the configuration and quantity you need. Include your process requirements if you would like help with selection.
View quote listThe DVP LC 41 is a single-stage, oil-lubricated rotary vane vacuum pump from DVP Vacuum Technology. It pumps 40 m³/h and reaches an ultimate pressure of 0.1 mbar absolute. Girovac supplies the LC 41 in the UK, stocks genuine DVP spares and oil, and services DVP pumps in-house. Price on application.
| Pumping speed | 40 m³/h (50 Hz) / 48 m³/h (60 Hz) |
|---|---|
| Ultimate pressure | 0.1 mbar |
| Motor power | 1.1 kW (single-phase) / 1.1 kW (three-phase, IE3) at 50 Hz |
| Weight | 43 kg |
| Oil type | DVP SW60 |
| Price | On application |
The LC 41 is part of DVP’s LC range — 40 m³/h, ultimate 0.1 mbar, selectable gas ballast. Oil-sealed rotary vane pumps like this one are the workhorses of industrial vacuum: the oil seals the clearances, lubricates the vanes and carries away heat, which is what lets a single-stage rotary vane pump hold a steady working vacuum under continuous duty.
DVP’s datasheet for the LC 41 does not list specific applications. Pumps in DVP’s LC range are used across vacuum packaging, handling and lifting, printing, laboratory and general industrial vacuum duties. If you tell us the process, volume and target pressure, we will confirm whether the LC 41 is the right choice.
| Nominal capacity (pumping speed) | 40 m³/h (50 Hz) / 48 m³/h (60 Hz) |
|---|---|
| Ultimate pressure (absolute, gas ballast closed) | 0.1 mbar |
| Ultimate pressure (absolute, gas ballast open) | 0.5 mbar |
| Continuous-duty working range | 400 to 0.1 mbar (abs) |
| Max. inlet pressure for water vapour (gas ballast open) | 14 mbar |
| Max. water-vapour pumping rate (gas ballast open) | 0.5 kg/h |
| Maximum inlet air temperature | 40 °C |
| Motor power | 1.1 kW (single-phase) / 1.1 kW (three-phase, IE3) at 50 Hz |
| Nominal speed | 1400 rpm (50 Hz) / 1700 rpm (60 Hz) |
| Noise level (UNI EN ISO 2151, K 3 dB) | 64 dB(A) at 50 Hz / 66 dB(A) at 60 Hz |
| Weight | 43 kg |
| Oil type | DVP SW60 |
| Oil quantity | 1.5–2 dm³ |
| Pump type | Single-stage, oil-lubricated rotary vane |
| DVP part number | 9601078 |
| Manufacturer | DVP Vacuum Technology |
Figures are taken from DVP’s published datasheet for the LC 41 (part number 9601078). Noise is measured to UNI EN ISO 2151. Need the pumping speed at your actual working pressure rather than the nominal figure? Ask us for the curve.
The closest alternatives by pumping speed are the DVP LC 20 and DVP LC 40. If you are between sizes, size on the volume to be evacuated and the time you have to do it in, not on the nominal figure alone.
| DVP LC 41 (this pump) | 40 m³/h (50 Hz) / 48 m³/h (60 Hz) · ultimate 0.1 mbar |
|---|---|
| DVP LC 20 | 20 m³/h (50 Hz) / 24 m³/h (60 Hz) · ultimate 2 mbar |
| DVP LC 40 | 40 m³/h (50 Hz) / 48 m³/h (60 Hz) · ultimate 0.1 mbar |
See the full DVP pump range or read our guide to the types of vacuum pump.
Established in 1983, with more than 40 years in the industrial vacuum sector, Girovac supplies, services and stocks spares for DVP vacuum pumps from our workshop in North Walsham, Norfolk. We can supply the LC 41 new, source genuine DVP spares, and repair, service or recondition DVP pumps. If you are pumping water vapour, use the gas ballast — it is what stops vapour condensing in the oil.
Routine care is straightforward: keep the oil clean and topped up, change it on schedule, and keep the inlet filter clear. Most cases of a not reaching ultimate vacuum come down to tired oil or a leak rather than a worn pump. See our DVP vacuum pump service guide for the full routine.
We do not list prices online. Every LC 41 is quoted to your application, duty cycle and phase requirement, including delivery to anywhere in the UK. Contact us for a quote on price, availability and technical advice.
The LC 41 reaches an ultimate pressure of 0.1 mbar absolute, operating continuously across 400 to 0.1 mbar (abs), with a nominal pumping speed of 40 m³/h (50 Hz) / 48 m³/h (60 Hz).
The LC 41 uses DVP SW60 rotary vane pump oil, with a charge of 1.5–2 dm³. Change it when it darkens or the achievable vacuum drops off. Girovac stocks genuine DVP oil.
The LC 41 is a single-stage, oil-lubricated (oil-sealed) rotary vane vacuum pump. Single-stage pumps of this type typically reach the 10⁻¹ mbar region; for deeper vacuum you would need a two-stage pump.
The LC 41 is rated at 1.1 kW (single-phase) / 1.1 kW (three-phase, IE3) at 50 Hz and weighs 43 kg. Tell us whether you need single-phase or three-phase when you enquire.
Girovac quotes the LC 41 on application rather than listing a price, because cost depends on phase, accessories and delivery. Contact us and we will come back with a firm price and lead time.
Yes. Established in 1983, with more than 40 years in the industrial vacuum sector, Girovac supplies, services and stocks spares for DVP vacuum pumps from our workshop in North Walsham, Norfolk. We service, repair and recondition DVP pumps including the LC 41, and stock genuine spares.
Download the original DVP LC 41 manufacturer datasheet (PDF). Check the model columns, supply frequency and operating conditions before comparing values.
Depending on the duty, compare DVP LC 205, DVP LC 305, DVP CPA Duplex. These are different configurations, not automatic replacements. Check working pressure, flow, gas load and installation requirements. Browse the complete DVP range for more options.
For rough-vacuum duties, review industrial vacuum dial gauges; for pump-down measurement into lower pressures, compare Pirani vacuum transducers. Match the instrument range and gas compatibility to the operating pressure. We can also quote vacuum gauge calibration at the relevant test points.
Send the required pressure, simultaneous demand and control requirements when discussing industrial vacuum systems. Consider pumps, pipework, filtration and instrumentation together.
| Manufacturer | DVP |
|---|---|
| Equipment type | Single Stage Oil Filled Pumps |
| Nominal pumping capacity | 40 m³/h (50 Hz) / 48 m³/h (60 Hz) |
| End / ultimate pressure | 0.1 mbar — absolute, gas ballast closed |
| Motor power | 1.1 kW (single-phase) / 1.1 kW (three-phase, IE3) at 50 Hz |
| Lubricant | DVP SW60 |
| Noise level | 64 dB(A) at 50 Hz / 66 dB(A) at 60 Hz — UNI EN ISO 2151, K 3 dB |
| Weight | 43 kg |
| DVP part number | 9601078 |
Send the pump model and part number when asking about a replacement. Compatibility depends on the equipment and operating conditions.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
What to check in your quotation · Delivery · Returns and faults
DVP LC 41 Lubricated Rotary Vane Vacuum Pump
Prefer to talk? 01692 660 117 · [email protected]
We use your details to respond to your enquiry. Read our privacy policy.

DVP

MIL'S

MIL'S

DVP
The GVPSV4 is an oil-lubricated single-stage rotary vane vacuum pump for air-conditioning, refrigeration and laboratory applications. Nominal pumping speed is 4 m³/h at 50 Hz.
View specificationsCompare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino