Find a pump, instrument or spare part by model, reference or technology. Compare the full product details before selecting a replacement.
All groups 105 Pumps & systems 101 Spares & service parts 4 101 matching listings for “oil-free pump” .
Pumps & systems (101) LEYBOLD
End / ultimate pressure 0.1 mbar gas ballast closed; 0.15 mbar one turn open
Electrical supply Voltage-specific single-phase 100, 115, 200 or 230 V; 50/60 Hz View product details → LEYBOLD
End / ultimate pressure 0.1 mbar gas ballast closed; 0.15 mbar one turn open
Electrical supply Voltage-specific single-phase 100, 115, 200 or 230 V; 50/60 Hz View product details → LEYBOLD
Peak speed: 1-phase 50/60 Hz or 3-phase 60 Hz 6.1 m³/h
Ordering options 6 manufacturer codes — see configuration table View product details → LEYBOLD
Peak speed: 1-phase 50/60 Hz or 3-phase 60 Hz 10.6 m³/h
Ordering options 6 manufacturer codes — see configuration table View product details → LEYBOLD
Peak speed: 1-phase 50/60 Hz or 3-phase 60 Hz 14.5 m³/h
Ordering options 6 manufacturer codes — see configuration table View product details → LEYBOLD
Peak speed: 1-phase 50/60 Hz or 3-phase 60 Hz 20 m³/h
Ordering options 6 manufacturer codes — see configuration table View product details → LEYBOLD
Reference: GV-LEY-VARODRY-SYSTEM-VDI-200
Ordering options 2 manufacturer codes — see configuration table View product details → LEYBOLD
Reference: GV-LEY-VARODRY-SYSTEM-VDI-400
Ordering options 2 manufacturer codes — see configuration table View product details → LEYBOLD
End / ultimate pressure 0.01 mbar without gas ballast
Electrical supply Three-phase, version-specific: 200/400 V ±10% at 50 Hz; 230/460 V or 200/380 V ±10% at 60 Hz View product details → LEYBOLD
End / ultimate pressure 0.01 mbar without gas ballast
Electrical supply Three-phase, version-specific: 200/400 V ±10% at 50 Hz; 230/460 V or 200/380 V ±10% at 60 Hz View product details → LEYBOLD
End / ultimate pressure 0.01 mbar without gas ballast
Electrical supply Three-phase, version-specific: 200/400 V ±10% at 50 Hz; 230/460 V or 200/380 V ±10% at 60 Hz View product details → LEYBOLD
End / ultimate pressure 0.01 mbar without gas ballast
Electrical supply Three-phase, version-specific: 200/400 V ±10% at 50 Hz; 230/460 V or 200/380 V ±10% at 60 Hz View product details → Need to check a replacement? Matching a model name does not confirm compatibility. Include the suffix, supply, connections and process duty in your replacement enquiry . Collect suitable items in your quote shortlist .