DVP
DVP LC 12 Lubricated Rotary Vane Vacuum Pump
- Nominal pumping capacity
- 12 m³/h (50 Hz) / 14 m³/h (60 Hz)
- End / ultimate pressure
- 2 mbar — absolute
- Motor power
- 0.45 kW (single-phase) / 0.37 kW (three-phase) at 50 Hz
MIL’S single-stage oil-lubricated vacuum pump: 513 m³/h nominal flow at 50 Hz and 496 m³/h PNEUROP pumping speed. Standard and HV versions have different end pressures; confirm the required version. View specifications, manufacturer curves and dimensions, or ask Girovac for a quotation.
Tell us the configuration and quantity you need. Include your process requirements if you would like help with selection.
View quote listThe E500.R is a larger oil-lubricated rotary vane pump with 513 m³/h nominal flow at 50 Hz. The European motor is rated at 11 kW, with a 14 litre oil charge. For HV duty at 1 mbar, the catalogue lists 266 m³/h; compare that figure with the required gas load rather than sizing solely from nominal flow.
EVISA uses oil-lubricated rotary vane technology with an integrated exhaust oil-mist filter. Tell Girovac the working pressure, process gas and operating duty so the pump and supporting equipment can be checked together.
Standard E500.R: ≤ 3 mbar without gas ballast at 50 and 60 Hz. The E500.R HV version is listed at ≤ 0.1 mbar at 50 Hz and ≤ 0.1 mbar at 60 Hz without gas ballast. Do not apply the HV figure to a standard pump.
With gas ballast fully open, the listed end vacuum is ≤ 5 mbar for the standard version and ≤ 1 mbar for HV, at both frequencies. Gas-ballast settings affect vapour handling and the pressure achieved. Specify the gas-ballast arrangement in the quotation.
The manufacturer plots below show evacuation of a 1,000 litre vessel and pumping speed against absolute inlet pressure. Follow the original 50 or 60 Hz line and gas-ballast legend. The low-pressure curves describe HV performance; they do not give a standard E500.R pump an HV pressure rating.

At 50 Hz, the catalogue gives 266 m³/h at 1 mbar for HV duty, compared with 496 m³/h PNEUROP pumping speed. Measurements are specified to PNEUROP 6602 at 20 °C. Actual evacuation time also depends on vessel conditions, pipework, leaks and process gas load. The graphs are vacuum-performance references, not electrical power-consumption curves.
The plotted open-gas-ballast end point and the tabulated fully-open end-vacuum value are not identical in this source. Use the table above for the stated rating and confirm the gas-ballast configuration when selecting from the curves.
The European version uses three-phase 400/690 v, 50 hz, with a 11 kW motor at 1,000 min⁻¹. The listed inlet is DN 80 / 3-inch BSP and the outlet is 3-inch BSP. Other regional versions can have different motors, voltages, connections and weights.

Check the drawing against the precise motor and pump reference being supplied. Allow access to the oil fill, drain, filters and cooling-air paths; the pump outline is not a service-clearance allowance. For a replacement, send a nameplate photograph and the existing installation dimensions.
The catalogue specifies 14 litres of MV99S 100% synthetic oil for the standard lubrication arrangement. An oxygen-service version needs its own approved lubrication and configuration; do not assume the standard oil specification applies.
The model section lists usual-maintenance kits at 3,000 hours and preventive-maintenance kits at 12,000 hours. Use the operating instructions and actual process conditions to set the service schedule, and quote the serial number when ordering a kit. Inlet filtration, liquid protection and gas-ballast options should be matched to the gas stream and installation.
Ask about EVISA servicing · Read the selection guides
Open the MIL’S EVISA E500.R section in the manufacturer catalogue (PDF, 6.4 MB). Printed pages 50–53 cover technical data, dimensions, references, accessories and performance curves. The PDF viewer starts at page 49; its file page count differs from the printed numbering by one.
Specification basis: MIL’S EVISA / EVISA ATEX catalogue supplied to Girovac. Figures reproduced from the manufacturer document. Listing expanded September 2026; confirm current model configuration, availability and applicable instructions with your quotation.
Nominal flow is 513 m³/h at 50 Hz and 616 m³/h at 60 Hz. PNEUROP pumping speed is 496 and 595 m³/h respectively. Use the performance at your working pressure when sizing the pump.
No. This listing covers standard and HV configurations. The standard version is listed at ≤ 3 mbar without gas ballast; the HV version reaches a different stated end vacuum. Specify the variant when enquiring.
The supplied catalogue specifies MV99S 100% synthetic oil and a 14 litre charge for the standard lubrication arrangement. Confirm the exact version and do not apply this specification to oxygen service.
Include the complete model and variant, working pressure, gas or vapour load, vessel volume and required cycle time. Add the electrical supply, connection details and any filters or controls. For an existing pump, include its serial number and a nameplate photo.
EVISA E400.R · EVISA E600.R · All MIL’S equipment
Select Compare on up to three listings to view their specifications together. Keep frequency, version and gas-ballast conditions alongside the numbers.
Compare the 0–25 mbar absolute capsule gauge for a defined low-pressure dial range with Pirani vacuum transducers for electronic measurement over a wider pressure span. portable meters and data loggers can help record pump-down behaviour. Choose by the actual working pressure and required accuracy, then check the gas and connection.
Yes. Use our vacuum gauge calibration service to specify the instrument, pressure points and certificate requirement. If your process relies on a displayed controller reading, tell us about the complete measuring chain.
| Manufacturer | MIL'S |
|---|---|
| Equipment type | Single Stage Rotary Pumps / Single Stage Oil Filled Pumps |
| Nominal pumping capacity | 513 m³/h at 50 Hz; 616 m³/h at 60 Hz |
| PNEUROP pumping speed (50 Hz) | 496 m³/h; PNEUROP 6602 at 20 °C |
| PNEUROP pumping speed (60 Hz) | 595 m³/h; PNEUROP 6602 at 20 °C |
| End / ultimate pressure | Standard: ≤ 3 mbar at 50/60 Hz; HV: ≤ 0.1 mbar at 50 Hz; ≤ 0.1 mbar at 60 Hz; without gas ballast |
| Inlet / outlet connections | DN 80 / 3-inch BSP / 3-inch BSP — European version |
| Motor power | 11 kW — European 50 Hz version |
| Electrical supply | Three-phase 400/690 V, 50 Hz — European version |
| Lubricant | MV99S 100% synthetic; standard lubrication specification |
| Noise level | 73 / 77 dB(A) — 50 / 60 Hz |
| Pumping speed at 1 mbar (HV, 50 Hz) | 266 m³/h; PNEUROP 6602 at 20 °C |
| Pumping speed at 1 mbar (HV, 60 Hz) | 320 m³/h; PNEUROP 6602 at 20 °C |
| End vacuum with fully opened gas ballast (HV) | ≤ 1 mbar at 50/60 Hz |
| End vacuum with fully opened gas ballast (standard) | ≤ 5 mbar at 50/60 Hz |
| Motor speed | 1,000 min⁻¹ — European version |
| Oil capacity | 14 litres |
| Weight with oil (European version) | 462 kg |
| Pumping technology | Single-stage oil-lubricated rotary vane |
Send the pump model and part number when asking about a replacement. Compatibility depends on the equipment and operating conditions.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
What to check in your quotation · Delivery · Returns and faults
MIL’S EVISA E500.R Rotary Vane Vacuum Pump
Prefer to talk? 01692 660 117 · [email protected]
We use your details to respond to your enquiry. Read our privacy policy.

DVP

MIL'S

MIL'S

DVP
With a Nominal Pumping Speed of 8M³/Hr @ 50Hz 10M³/Hr @ 60Hz The GVPSV8 were specifically designed for the AC/R sector and for Laboratory…
View specificationsCompare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino