MIL’S single-stage oil-lubricated vacuum pump: 513 m³/h nominal flow at 50 Hz and 496 m³/h PNEUROP pumping speed. Standard and HV versions have different end pressures; confirm the required version. View specifications, manufacturer curves and dimensions, or ask Girovac for a quotation.
MIL’S EVISA E500.R: selecting the right configuration
The E500.R is a larger oil-lubricated rotary vane pump with 513 m³/h nominal flow at 50 Hz. The European motor is rated at 11 kW, with a 14 litre oil charge. For HV duty at 1 mbar, the catalogue lists 266 m³/h; compare that figure with the required gas load rather than sizing solely from nominal flow.
EVISA uses oil-lubricated rotary vane technology with an integrated exhaust oil-mist filter. Tell Girovac the working pressure, process gas and operating duty so the pump and supporting equipment can be checked together.
End vacuum and gas-ballast options
Standard E500.R: ≤ 3 mbar without gas ballast at 50 and 60 Hz. The E500.R HV version is listed at ≤ 0.1 mbar at 50 Hz and ≤ 0.1 mbar at 60 Hz without gas ballast. Do not apply the HV figure to a standard pump.
With gas ballast fully open, the listed end vacuum is ≤ 5 mbar for the standard version and ≤ 1 mbar for HV, at both frequencies. Gas-ballast settings affect vapour handling and the pressure achieved. Specify the gas-ballast arrangement in the quotation.
Performance curves and pump-down time
The manufacturer plots below show evacuation of a 1,000 litre vessel and pumping speed against absolute inlet pressure. Follow the original 50 or 60 Hz line and gas-ballast legend. The low-pressure curves describe HV performance; they do not give a standard E500.R pump an HV pressure rating.
Source: MIL’S EVISA / EVISA ATEX catalogue, printed page 53 (PDF page 52). Original manufacturer pressure-versus-time and flow-versus-pressure graphs; frequency and gas-ballast legend retained. View full-size image.
At 50 Hz, the catalogue gives 266 m³/h at 1 mbar for HV duty, compared with 496 m³/h PNEUROP pumping speed. Measurements are specified to PNEUROP 6602 at 20 °C. Actual evacuation time also depends on vessel conditions, pipework, leaks and process gas load. The graphs show vacuum performance; motor power is listed separately in the specifications.
Use the listed fully-open gas-ballast rating for selection. For intermediate settings, ask us to confirm the matching performance curve.
Dimensions, connections and electrical supply
The European version uses three-phase 400/690 v, 50 hz, with a 11 kW motor at 1,000 min⁻¹. The listed inlet is DN 80 / 3-inch BSP and the outlet is 3-inch BSP. Other regional versions can have different motors, voltages, connections and weights.
Source: MIL’S EVISA / EVISA ATEX catalogue, printed page 51 (PDF page 50). Original manufacturer dimensions in millimetres, with inches in brackets. View full-size image.
Check the drawing against the precise motor and pump reference being supplied. Allow access to the oil fill, drain, filters and cooling-air paths; the pump outline is not a service-clearance allowance. For a replacement, send a nameplate photograph and the existing installation dimensions.
Oil, service parts and accessories
The catalogue specifies 14 litres of MV99S 100% synthetic oil for the standard lubrication arrangement. An oxygen-service version needs its own approved lubrication and configuration; do not assume the standard oil specification applies.
The model section lists usual-maintenance kits at 3,000 hours and preventive-maintenance kits at 12,000 hours. Use the operating instructions and actual process conditions to set the service schedule, and quote the serial number when ordering a kit. Inlet filtration, liquid protection and gas-ballast options should be matched to the gas stream and installation.
Nominal flow is 513 m³/h at 50 Hz and 616 m³/h at 60 Hz. PNEUROP pumping speed is 496 and 595 m³/h respectively. Use the performance at your working pressure when sizing the pump.
Is every EVISA E500.R an HV pump?
No. This listing covers standard and HV configurations. The standard version is listed at ≤ 3 mbar without gas ballast; the HV version reaches a different stated end vacuum. Specify the variant when enquiring.
Which oil does the EVISA E500.R use?
MIL’S specifies MV99S 100% synthetic oil and a 14 litre charge for the standard lubrication arrangement. Confirm the exact version and do not apply this specification to oxygen service.
What should I send for a quotation?
Include the complete model and variant, working pressure, gas or vapour load, vessel volume and required cycle time. Add the electrical supply, connection details and any filters or controls. For an existing pump, include its serial number and a nameplate photo.
Select Compare on up to three listings to view their specifications together. Keep frequency, version and gas-ballast conditions alongside the numbers.
Vacuum measurement and calibration questions
Which vacuum gauges could be useful with this equipment?
Can Girovac arrange calibration for the measuring instruments?
Yes. Use our vacuum gauge calibration service to specify the instrument, pressure points and certificate requirement. If your process relies on a displayed controller reading, tell us about the complete measuring chain.
Specifications
Manufacturer
MIL'S
Equipment type
Single Stage Rotary Pumps / Single Stage Oil Filled Pumps
Nominal pumping capacity
513 m³/h at 50 Hz; 616 m³/h at 60 Hz
PNEUROP pumping speed (50 Hz)
496 m³/h; PNEUROP 6602 at 20 °C
PNEUROP pumping speed (60 Hz)
595 m³/h; PNEUROP 6602 at 20 °C
End / ultimate pressure
Standard: ≤ 3 mbar at 50/60 Hz; HV: ≤ 0.1 mbar at 50 Hz; ≤ 0.1 mbar at 60 Hz; without gas ballast
Inlet / outlet connections
DN 80 / 3-inch BSP / 3-inch BSP — European version
Motor power
11 kW — European 50 Hz version
Electrical supply
Three-phase 400/690 V, 50 Hz — European version
Lubricant
MV99S 100% synthetic; standard lubrication specification
Noise level
73 / 77 dB(A) — 50 / 60 Hz
Pumping speed at 1 mbar (HV, 50 Hz)
266 m³/h; PNEUROP 6602 at 20 °C
Pumping speed at 1 mbar (HV, 60 Hz)
320 m³/h; PNEUROP 6602 at 20 °C
End vacuum with fully opened gas ballast (HV)
≤ 1 mbar at 50/60 Hz
End vacuum with fully opened gas ballast (standard)
≤ 5 mbar at 50/60 Hz
Motor speed
1,000 min⁻¹ — European version
Oil capacity
14 litres
Weight with oil (European version)
462 kg
Pumping technology
Single-stage oil-lubricated rotary vane
Parts, consumables and workshop support
Send the pump model and part number when asking about a replacement. Compatibility depends on the equipment and operating conditions.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.