CONTVAC
GVPDK90
The GVPDK90 is an oil-lubricated two-stage rotary vane vacuum pump for industrial and laboratory use. Nominal pumping speed is 90 m³/h at 50 Hz.
View specificationsThe NEO D 65 is a two-stage oil-sealed rotary vane pump with integrated exhaust oil-mist filtration for laboratory and industrial roughing and backing. Actual pumping speed is 63 m³/h at 50 Hz or 76 m³/h at 60 Hz. Select the motor, oil and gas-ballast arrangement for the process and the available supply.
Leybold NEO D manufacturer range photograph showing a single-phase pump; three-phase motors and larger models differ.
Part of the Leybold NEO D two-stage rotary vane pumps family. Compare the range and other model options.
Tell us the configuration and quantity you need. Include your process requirements if you would like help with selection.
View quote listThe NEO D 65 is a two-stage oil-sealed rotary vane pump with integrated exhaust oil-mist filtration for laboratory and industrial roughing and backing. Actual pumping speed is 63 m³/h at 50 Hz or 76 m³/h at 60 Hz. Select the motor, oil and gas-ballast arrangement for the process and the available supply.
The D 65 is the highest-capacity NEO D in this group at 63 m³/h actual speed at 50 Hz. The manual lists three-phase motor versions; a standard direct single-phase D 65 is not assumed.
| Specification | Details |
|---|---|
| Actual pumping speed, 50 / 60 Hz | 63 / 76 m³/h |
| Ultimate pressure | ≤0.008 mbar without gas ballast; ≤0.1 mbar with standard gas ballast |
| Inlet / exhaust | DN40 ISO-KF / DN40 ISO-KF |
| Nominal displacement, 50 / 60 Hz | 74 / 89 m³/h |
| Electrical supply | Three-phase world motor; 400 V / 50 Hz supported |
| Oil capacity | 3 litres |
| Net mass with oil | 88 kg |
| Water-vapour tolerance / capacity | 10 mbar / 0.5 kg/h with standard gas ballast |
| Ambient operation | 12–40 °C |
| Exhaust oil-mist filtration | Integrated; maintain filter and oil return as instructed |
Speed and pressure figures follow the manual’s DIN 28400 conditions for standard variants with the recommended oil and standard gas ballast. Nominal displacement differs from actual pumping speed. Achieved chamber pressure depends on gas load, conductance, oil condition and configuration.
Select a three-phase supply for the standard D 65 motor. The three-phase world-motor version supports UK 400 V, 50 Hz operation when correctly connected. Motor protection and wiring must match the nameplate.
The standard order codes below specify LVO702 oil in manual C7. Other oil builds have different suffixes; use the lubricant specified for the supplied pump and process. Standard three-position, permanent and electromagnetic gas-ballast arrangements are not interchangeable order selections.
The NEO D combines oil-sealed compression with integrated exhaust mist separation and oil return. This reduces external filter plumbing, but it does not remove oil-service requirements or make hazardous exhaust safe to release into the room. Route exhaust for the actual gas and maintain the filter and oil return according to the manual.
Oil-level, temperature and exhaust-filter monitoring accessories are selected separately. A controller or sensor shown in application material is not automatically included. Confirm sensors, cables, inlet protection and any vacuum isolation valve on the quotation.
Gas ballast improves handling of suitable condensable vapours but raises ultimate pressure. Provide the full gas composition and vapour load before selecting oil or accessories. The integrated anti-suckback valve is not a safety isolation device; an application requiring assured vacuum isolation needs a separate assessment.
These references identify specific builds for an enquiry. This model-level listing has no single manufacturer part number; confirm the selected build and current availability with Girovac.
| Specification | Details |
|---|---|
| Order code 970402V | Three-phase world motor, 180–264 / 342–457 V at 50 Hz; 180–264 / 342–506 V at 60 Hz, standard gas ballast, LVO702 |


Specification source: 300731504_C7, July 2026, technical table page 22, drawings pages 24–25, ordering pages 30–34 and installation sections. Match the document revision to the pump supplied.
Explore the NEO D family guide or compare NEO D 16, NEO D 25, NEO D 40. Return to the Leybold brand guide.
Also compare TRIVAC L two-stage pumps and ECODRY dry pumps when selecting the compression technology.
For a NEO D 65 quotation, send chamber volume, target pressure, gas and vapour composition, continuous throughput, pump-down time, cycle frequency, inlet and exhaust connections, electrical supply and quantity. Include control, filtration and installation-space requirements. Girovac will confirm the configuration, included equipment, price and delivery.
| Manufacturer | LEYBOLD |
|---|---|
| Equipment type | Two Stage Rotary Pumps |
| End / ultimate pressure | ≤0.008 mbar without gas ballast; ≤0.1 mbar with standard gas ballast |
| Electrical supply | Three-phase world motor; 400 V / 50 Hz supported |
| Actual pumping speed, 50 / 60 Hz | 63 / 76 m³/h |
| Inlet / exhaust | DN40 ISO-KF / DN40 ISO-KF |
| Nominal displacement, 50 / 60 Hz | 74 / 89 m³/h |
| Oil capacity | 3 litres |
| Net mass with oil | 88 kg |
| Water-vapour tolerance / capacity | 10 mbar / 0.5 kg/h with standard gas ballast |
| Ambient operation | 12–40 °C |
| Exhaust oil-mist filtration | Integrated; maintain filter and oil return as instructed |
Send the pump model and part number when asking about a replacement. Compatibility depends on the equipment and operating conditions.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
What to check in your quotation · Delivery · Returns and faults
Leybold NEO D 65 Two-Stage Rotary Vane Vacuum Pump
Prefer to talk? 01692 660 117 · [email protected]
We use your details to respond to your enquiry. Read our privacy policy.

CONTVAC
The GVPDK90 is an oil-lubricated two-stage rotary vane vacuum pump for industrial and laboratory use. Nominal pumping speed is 90 m³/h at 50 Hz.
View specifications
CONTVAC
The GVPDK75 is an oil-lubricated two-stage rotary vane vacuum pump for industrial and laboratory use. Nominal pumping speed is 75 m³/h at 50 Hz.
View specifications
DVP

CONTVAC
Compare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino