Leybold NOVADRY NDi 400 Dry Screw Vacuum Pump
- Ordering options
- 2 manufacturer codes — see configuration table
The VARODRY VD 200 is an air-cooled dry screw vacuum pump for industrial roughing, drying, degassing and suitable backing duties requiring a lower ultimate pressure. The manufacturer’s C5 operating instructions specify 185 m³/h maximum pumping speed without gas ballast and 0.01 mbar ultimate pressure without gas ballast.
Leybold VARODRY manufacturer range photograph showing the enclosed pump; motor and configuration depend on the model ordered.
Part of the Leybold VARODRY pumps and VDi systems family. Compare the range and other model options.
Tell us the configuration and quantity you need. Include your process requirements if you would like help with selection.
View quote listQuote the complete Leybold ordering code when requesting a price. The entries below identify different configurations; voltage, flange, lubricant, cooling and interfaces must match the installation. Availability and supplied equipment are confirmed with the quotation.
| Product code | Manufacturer designation | Configuration detail |
|---|---|---|
| 10110200V01 | VARODRY VD 200 OEM HD/O2, 50Hz, 200/400 | See designation and selected-code documentation |
| 10110200V02 | VARODRY VD 200 OEM HD/O2, 60Hz, 230/460 | See designation and selected-code documentation |
| 10110200V03 | VARODRY VD 200 OEM HD/O2, 60Hz, 200/380 | See designation and selected-code documentation |
| 111200V10 | VARODRY VD 200 – 400V 50Hz | See designation and selected-code documentation |
| 111200V11 | VARODRY VD 200 – 230/460V 60Hz | See designation and selected-code documentation |
| 111200V12 | VARODRY VD 200 OEM – 50Hz 200/400V | See designation and selected-code documentation |
| 111200V12JYT | VARODRY VD 200 OEM, 50Hz, 200/400V, JYT | See designation and selected-code documentation |
| 111200V13 | VARODRY VD 200 OEM – 60Hz 230/460V | See designation and selected-code documentation |
| 111200V15 | VARODRY VD 200 – 400V 50Hz Purge | See designation and selected-code documentation |
| 111200V16 | VARODRY VD 200 – 230/460V 60Hz Purge | See designation and selected-code documentation |
| 111200V21 | VARODRY VD 200 – 200/380V 60Hz | See designation and selected-code documentation |
| 111200V22 | VARODRY VD 200 OEM – 60Hz 200/380V | See designation and selected-code documentation |
| 111200V26 | VARODRY VD 200 – 200/380V 60Hz Purge | See designation and selected-code documentation |
| 111200V35 | VARODRY VD 200 HD/O2 – 50Hz 200/400V Purge | See designation and selected-code documentation |
| 111200V36 | VARODRY VD 200 HD/O2 – 60Hz 230/460V Purge | See designation and selected-code documentation |
| 111200V37 | VARODRY VD 200 HD/O2 – 60Hz 200/380V Purge | See designation and selected-code documentation |
The VARODRY VD 200 is an air-cooled dry screw vacuum pump for industrial roughing, drying, degassing and suitable backing duties requiring a lower ultimate pressure. The manufacturer’s C5 operating instructions specify 185 m³/h maximum pumping speed without gas ballast and 0.01 mbar ultimate pressure without gas ballast.
The 200 is the largest capacity in this group at 185 m³/h in the C5 manual. Its standard discharge-pressure limit differs from the smaller models, so assess the exhaust system as part of selection.
| Specification | Details |
|---|---|
| Maximum pumping speed | 185 m³/h without gas ballast; ±5%, C5 manual |
| Ultimate pressure | 0.01 mbar without gas ballast |
| Inlet / exhaust | G 2 in / G 1½ in |
| Electrical supply | Three-phase, version-specific: 200/400 V ±10% at 50 Hz; 230/460 V or 200/380 V ±10% at 60 Hz |
| Maximum current, 400 V / 50 Hz | 7.5 A; selected motor and protection must match |
| Water-vapour capacity with gas ballast | 6.9 kg/h; depends on installed configuration |
| Water-vapour tolerance with gas ballast | 60 mbar; installed configuration applies |
| Maximum discharge pressure above ambient | 100 mbar; up to 200 mbar only after inlet-condition review |
| Dimensions (L × W × H) | 1060 × 599 × 428 mm; standard envelope, check chosen connections |
| Mass | Approximately 140 kg |
| Cooling / ambient | Air-cooled; 0–40 °C |
The C5 operating manual is used for the ratings above. Some brochures and manufacturer overview pages give different figures for the 160/200 models; confirm the supplied revision and pressure-speed curve with the quotation. Gas ballast and exhaust backpressure affect performance.
For a UK 400 V, 50 Hz installation, specify the matching three-phase version. These are motor-terminal connections, with supply cable, isolation and motor protection selected for the installation. A domestic plug and mains lead are not assumed. Confirm the full order code, nameplate, phase sequence and starting arrangement.
Allow clear cooling airflow and space for belt and silencer service. Select inlet filtration and exhaust routing for the actual process. Above 1000 m installation altitude, request manufacturer review. An optional external variable-frequency drive must remain within the permitted motor speed; do not assume flow scales linearly with speed.
Gas ballast helps prevent condensation but changes attainable pressure. Water-vapour figures apply only to the stated configuration. Specify water load, cleaning procedures, particles and all process gases; the pump alone does not establish suitability for a complete food process or hazardous atmosphere.
VARODRY reaches a lower no-gas-ballast ultimate pressure than NOVADRY, but the required process pressure must still be assessed under load. Manual gas-ballast and purge-equipped builds need separate selection. Inlet and exhaust seal purge have different functions and require the correct gas supply and controls.
OEM, HD/O₂ and other special builds are distinct configurations. The standard ratings here do not certify oxygen service, ATEX operation or compatibility with corrosive gases. Provide the application for a specific configuration proposal.
These references identify specific builds for an enquiry. This model-level listing has no single manufacturer part number; confirm the selected build and current availability with Girovac.
| Specification | Details |
|---|---|
| Order code 111200V10 | 50 Hz, three-phase 200/400 V ±10% |
| Order code 111200V11 | 60 Hz, three-phase 230/460 V ±10% |
| Order code 111200V21 | 60 Hz, three-phase 200/380 V ±10% |


Specification source: 300766038_002_C5, technical data pages 13–14; installation and accessory sections. Match the document revision to the pump supplied.
Explore the VARODRY family guide or compare VARODRY 65, VARODRY 100, VARODRY 160. Return to the Leybold brand guide.
Compare NOVADRY for rough-vacuum duties. Assess required pressure under gas load before choosing a range.
For a VARODRY VD 200 quotation, send chamber volume, target pressure, gas and vapour composition, continuous throughput, pump-down time, cycle frequency, inlet and exhaust connections, electrical supply and quantity. Include control, filtration and installation-space requirements. Girovac will confirm the configuration, included equipment, price and delivery.
| Manufacturer | LEYBOLD |
|---|---|
| Equipment type | Dry Screw Vacuum Pumps |
| End / ultimate pressure | 0.01 mbar without gas ballast |
| Electrical supply | Three-phase, version-specific: 200/400 V ±10% at 50 Hz; 230/460 V or 200/380 V ±10% at 60 Hz |
| Maximum pumping speed | 185 m³/h without gas ballast; ±5%, C5 manual |
| Ordering options | 16 manufacturer codes — see configuration table |
| Inlet / exhaust | G 2 in / G 1½ in |
| Maximum current, 400 V / 50 Hz | 7.5 A; selected motor and protection must match |
| Water-vapour capacity with gas ballast | 6.9 kg/h; depends on installed configuration |
| Water-vapour tolerance with gas ballast | 60 mbar; installed configuration applies |
| Maximum discharge pressure above ambient | 100 mbar; up to 200 mbar only after inlet-condition review |
| Dimensions (L × W × H) | 1060 × 599 × 428 mm; standard envelope, check chosen connections |
| Mass | Approximately 140 kg |
| Cooling / ambient | Air-cooled; 0–40 °C |
Send the pump model and part number when asking about a replacement. Compatibility depends on the equipment and operating conditions.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
What to check in your quotation · Delivery · Returns and faults
Leybold VARODRY VD 200 Dry Screw Vacuum Pump
Prefer to talk? 01692 660 117 · [email protected]
We use your details to respond to your enquiry. Read our privacy policy.

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD
Compare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino