EDWARDS
Edwards D-LAB 10-8 Diaphragm Vacuum Pump
- Nominal pumping capacity
- 0.6 m³/h (10 l/min, published) at 50 Hz
- End / ultimate pressure
- 8 mbar at 50 Hz
- Motor power
- 90 W
Compact oil-free diaphragm pump for non-aggressive gases. AC and 24 V DC versions, NW16 inlet and typical ultimate pressure below 2 mbar. Confirm the application and complete supply scope.
Part of the Edwards XDD1 and D-LAB Diaphragm Vacuum Pumps family. Compare the range and other model options.
Tell us the configuration and quantity you need. Include your process requirements if you would like help with selection.
View quote listEdwards XDD1 is an oil-free diaphragm pump for non-aggressive gases in safe-area applications. It can serve a suitable small laboratory duty or back a compatible compound turbomolecular pump. Its own typical ultimate pressure is below 2 mbar; the much lower pressure obtainable with a turbo stage is a complete-system result.
| Specification | Details |
|---|---|
| Pumping speed, AC at 50 Hz | 1.2 m³/h |
| Typical ultimate pressure | <2 mbar |
| Inlet | NW16 |
| Power options | AC Mk2 / 24 V DC Mk3 |
| AC at 60 Hz | 1.4 m³/h |
| DC speed range | 0.6–1.8 m³/h at 600–2400 rpm |
| Ambient temperature | 10–40 °C |
The AC Mk2 version (published reference A74602983) is listed for 100–115 V at 50/60 Hz, 120 V at 60 Hz and 220–230 V at 50/60 Hz. The UK mains selection therefore needs the 220–230 V configuration checked on the nameplate. Published motor power is 80 W and mass 7.3 kg.
The Mk3 DC version (A74603991) uses 24 V DC. At the factory setting of 1700 rpm its published speed is 1.4 m³/h; at 600 rpm it is 0.6 m³/h and at 2400 rpm it is 1.8 m³/h. Published motor power is 64 W and mass 4.5 kg. Confirm the power supply, controller, cable and required operating speed. AC and DC are configuration choices, not interchangeable electrical connections.
The inlet is NW16. The exhaust silencer can be removed to connect an exhaust line using a 1/8-inch BSP fitting. Maximum permitted inlet pressure is 1 bar absolute. Check the exhaust route and process compatibility before installation.
The manufacturer lists a separately specified 2 m UK mains cable with 3 A plug, A50516000, and diaphragm service kit A74601800. Confirm the supplied scope and kit compatibility against the exact pump version. For more aggressive gases, discuss the D-LAB range and process protection rather than assuming XDD1 compatibility.
XDD1 specifications, curves, dimensions and ordering information (PDF)
Source: Edwards datasheet 3601-0472-01, technical data and ordering tables. Manufacturer photograph illustrates AC and DC variants; your quotation identifies the supplied version.
Edwards diaphragm pump comparison · T-Station complete pumping stations · Laboratory vacuum selection
Tell us the chamber volume or required flow, working and target pressures, gas and vapour composition, operating hours, electrical supply and connections. For a replacement, include the complete nameplate and serial number. Confirm the pump, accessories and controls included in your quotation.
Repair and servicing support · Spares and identification · Choose vacuum measurement
| Manufacturer | EDWARDS |
|---|---|
| Equipment type | Diaphragm Vacuum Pumps / Dry Vacuum Pumps / Medium Vacuum Pump |
| Nominal pumping capacity | 1.2 m³/h (AC, 50 Hz) |
| End / ultimate pressure | <2 mbar (typical) |
| Inlet / outlet connections | NW16 inlet; exhaust silencer or 1/8-inch BSP |
| Power options | AC Mk2 / 24 V DC Mk3 |
| AC at 60 Hz | 1.4 m³/h |
| DC speed range | 0.6–1.8 m³/h at 600–2400 rpm |
| Ambient temperature | 10–40 °C |
Send the pump model and part number when asking about a replacement. Compatibility depends on the equipment and operating conditions.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
What to check in your quotation · Delivery · Returns and faults
Edwards XDD1 Diaphragm Vacuum Pump
Prefer to talk? 01692 660 117 · [email protected]
We use your details to respond to your enquiry. Read our privacy policy.

EDWARDS

LEYBOLD

EDWARDS

There are a number of specialist simulation software tools available to the vacuum fraternity. PumpCalc is a simulation package for “simple systems” (i.e.
View specificationsCompare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino