CONTVAC
GVPDK3
Dual Stage (2 stage) With a Nominal Pumping Speed of 3M³/Hr @ 50Hz This lubricated rotary vane dual stage pump is designed to be used…
View specificationsThe DVP DC 16DEX is a rotary vane vacuum pump. The documented capacity is 17 / 21 m³/h (50 / 60 Hz). Total final pressure is 0.005 mbar. Ask Girovac to match the configuration to your duty and electrical supply.
Tell us the configuration and quantity you need. Include your process requirements if you would like help with selection.
View quote listThe DVP DC 16DEX is a rotary vane vacuum pump. The documented capacity is 17 / 21 m³/h (50 / 60 Hz). Total final pressure is 0.005 mbar. Ask Girovac to match the configuration to your duty and electrical supply.
Choose this oil-sealed pump around the required pumping speed at operating pressure, not its lowest pressure alone. Include chamber volume, pump-down time, gas composition and vapour load. Total and partial final pressure are different measurements; use the total-pressure figure for a like-for-like selection.
Internal ATEX application only: the datasheet marking is II 3/- G Ex h IIC T4 X Gc. The pump must be installed outside an ATEX-classified area. Process and ambient temperatures must be 12–40°C, and the specified minimum pressure must be reached within 20 minutes. Submit the gas and installation assessment for model confirmation; the EX suffix does not permit installation in an external explosive atmosphere.
| Specification | Manufacturer data |
|---|---|
| Model | DVP DC 16DEX |
| DVP catalogue code | 9602028 |
| Nominal pumping capacity | 17 / 21 m³/h (50 / 60 Hz) |
| Total final pressure (absolute) | 0.005 mbar |
| Number of stages | 2 |
| Motor power | 0.75 / 0.90 kW (1~); 0.55 / 0.66 kW (3~), 50 / 60 Hz |
| PNEUROP pumping speed | 16 / 17 m³/h (50 / 60 Hz) |
| Lubricant | DVP SW100 |
| Inlet / outlet connections | DN25 / DN25 |
Values apply to the stated model and conditions. Where two figures are shown, follow the 50 / 60 Hz order in the label. Confirm the motor, connections and supplied accessories in your quotation.
Download the original DVP DC 16DEX datasheet (PDF). The original document includes its revision information and any additional model-specific conditions.

Compare DVP RD 2D, DVP RC 4M, DVP RC 4D. Check the working pressure, capacity and motor rather than choosing by the model number alone. Browse the full DVP range.
A Pirani vacuum transducer is a useful starting point for measuring pump-down into lower pressures. Check its measuring range, gas correction and process compatibility. Measure at the chamber or point of use when that is the pressure your process depends on. Gauge calibration can be specified around the operating range and required test points.
Use the complete model, serial number and manufacturer oil specification. This datasheet specifies DVP SW100. Different suffixes and gear compartments can require different lubricants. See vacuum oils and greases and send the nameplate details when requesting parts.
Send the model, required flow at working pressure, gas or vapour, operating hours, electrical supply and any installation restrictions. For a replacement, include a nameplate photograph. We will confirm the proposed configuration, price and lead time before ordering.
Discuss the complete duty when reviewing industrial vacuum systems. A central installation also needs matched controls, filtration, pipework and pressure measurement; pump capacity alone is not the system specification.
Call 01692 660 117 or use the product enquiry form. Give us the model and working conditions so we can check the equipment and supporting accessories together.
| Manufacturer | DVP |
|---|---|
| Equipment type | Two Stage Rotary Pumps |
| Nominal pumping capacity | 17 / 21 m³/h (50 / 60 Hz) |
| End / ultimate pressure | 0.005 mbar — absolute |
| Inlet / outlet connections | DN25 / DN25 |
| Motor power | 0.75 / 0.90 kW (1~); 0.55 / 0.66 kW (3~), 50 / 60 Hz |
| Lubricant | DVP SW100 |
| Model | DC 16DEX |
| DVP catalogue code | 9602028 |
| Number of stages | 2 |
| PNEUROP pumping speed | 16 / 17 m³/h (50 / 60 Hz) |
Send the pump model and part number when asking about a replacement. Compatibility depends on the equipment and operating conditions.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
What to check in your quotation · Delivery · Returns and faults
DVP DC 16DEX Rotary Vane Vacuum Pump
Prefer to talk? 01692 660 117 · [email protected]
We use your details to respond to your enquiry. Read our privacy policy.

CONTVAC
Dual Stage (2 stage) With a Nominal Pumping Speed of 3M³/Hr @ 50Hz This lubricated rotary vane dual stage pump is designed to be used…
View specifications
DVP

DVP

CONTVAC
GVPDK50 two-stage rotary vane vacuum pump — UK supply, spares & servicing from Girovac.
View specificationsCompare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino