Hot Cathode / Pirani Ultra-high Vacuum Gauges
- Pressure reference
- Absolute
- Measuring range
- 1000 to 5 × 10⁻¹⁰ mbar
- Measurement principle
- Pirani and Bayard–Alpert; gas-dependent
A Pirani transducer for tracking pump-down and process pressure from atmosphere into fine vacuum. Digital and analogue interface configurations allow integration with compatible controllers and plant systems.
Tell us the configuration and quantity you need. Include your process requirements if you would like help with selection.
View quote listA Pirani transducer for tracking pump-down and process pressure from atmosphere into fine vacuum. Digital and analogue interface configurations allow integration with compatible controllers and plant systems.
Specify the gas and your control interface. Select the actual output version rather than assuming every connector is present. A replaceable sensor head and optional local display are available within this family.
No. Pirani measurement depends on heat transfer through the gas. State the gas or mixture so the interpretation and correction settings can be checked.
Yes. Tell us the operating range, required test points and certificate requirement. We will confirm the calibration option for the selected instrument before quoting. Discuss vacuum gauge calibration.
Compare cold-cathode / Pirani gauges and vacuum gauge controllers. Check the pressure reference, measurement range and output rather than selecting by connection alone.
For a turbo-pumped chamber, consider the measurement requirement alongside the nEXT85D turbomolecular pump. Measure at the point that matters to the process and select the gauge for the working pressure, gas and interface. A pump’s ultimate-pressure specification is not a substitute for a chamber measurement.
Send the pressure range and reference (absolute or relative), process gas, connection, quantity and required delivery date. Include the existing model or a photograph for replacement enquiries.
Compare vacuum gauge types or enquire about this instrument.
| Equipment type | Vacuum gauges & instrumentation |
|---|---|
| Pressure reference | Absolute |
| Measuring range | 1000 to 1 × 10⁻⁴ mbar |
| Measurement principle | Pirani; gas-dependent |
| Accuracy | About ±30% of reading at 1000–20 mbar; ±10% at 20–0.002 mbar |
| Supply | 20–30 V DC |
| Interfaces | RS485; 0–10 V, EtherCAT or PROFINET options vary by version |
| Connection | DN16 KF or DN16 CF-F |
| Response time | 40 ms |
| Standard overload limit | 10 bar absolute |
Send the gauge model, pressure range and process details for calibration, replacement or compatibility advice.
Confirm the range, pressure reference, connection, electrical output and whether cables, a controller or calibration are included.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
What to check in your quotation · Delivery · Returns and faults
Digital Pirani Vacuum Transducers
Prefer to talk? 01692 660 117 · [email protected]
We use your details to respond to your enquiry. Read our privacy policy.
The 2 Filamnets required for the SPECTRON Leak Detectors. For Use In: Edwards Spectron 300E Leak Detector Edwards Spectron 3000 Leak Detector Edwards…
View specificationsCompare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino