DVP
DVP XC 905 Vacuum System
- Nominal pumping capacity
- 915 / 1095 m³/h (50 / 60 Hz)
- End / ultimate pressure
- 0.1 mbar (gas ballast closed) — absolute
- Motor power
- 3 × 7.5 / 3 × 9 kW (50 / 60 Hz; three-phase)
The DVP CBL Booster Systems is a vacuum system. Total final pressure is 0.006 or 0.009 mbar, model-dependent; measured at booster inlet. Ask Girovac to match the configuration to your duty and electrical supply.
Tell us the configuration and quantity you need. Include your process requirements if you would like help with selection.
View quote listThe DVP CBL Booster Systems is a vacuum system. Total final pressure is 0.006 or 0.009 mbar, model-dependent; measured at booster inlet. Ask Girovac to match the configuration to your duty and electrical supply.
For a packaged or central vacuum installation, list each user, its operating pressure and which users run together. Agree the receiver, controls, filtration and standby requirement as part of the quotation. Installed pump capacity alone does not establish performance at the far end of the pipework.
An engineered booster and backing-pump package. Use the complete system curve at the intended inlet pressure; adding the nominal capacities of booster and primary pump does not give system pumping speed.
| Specification | Manufacturer data |
|---|---|
| Model | DVP CBL Booster Systems |
| Documented configurations | 106/300, 205/500, 305/500, 305/1000, 2×305/1500, 2×305/2000, 3×305/3000 |
| Pump arrangement | BCA lobe booster with LC primary pump(s) |
| Capacity at 5 mbar | 239–3100 m³/h at 50 Hz; 246–3125 m³/h at 60 Hz, depending on configuration and stated curve limits |
| Total final pressure (absolute) | 0.006 or 0.009 mbar, model-dependent; measured at booster inlet |
Values apply to the stated model and conditions. Where two figures are shown, follow the 50 / 60 Hz order in the label. Confirm the motor, connections and supplied accessories in your quotation.
Download the original DVP CBL Booster Systems datasheet (PDF). The original document includes its revision information and any additional model-specific conditions.

Compare DVP XC 405, DVP XC 605, DVP XC 905. Check the working pressure, capacity and motor rather than choosing by the model number alone. Browse the full DVP range.
A Pirani vacuum transducer is a useful starting point for measuring pump-down into lower pressures. Check its measuring range, gas correction and process compatibility. Measure at the chamber or point of use when that is the pressure your process depends on. Gauge calibration can be specified around the operating range and required test points.
Use the complete model, serial number and manufacturer oil specification. Different suffixes and gear compartments can require different lubricants. See vacuum oils and greases and send the nameplate details when requesting parts.
Send the model, required flow at working pressure, gas or vapour, operating hours, electrical supply and any installation restrictions. For a replacement, include a nameplate photograph. We will confirm the proposed configuration, price and lead time before ordering.
Call 01692 660 117 or use the product enquiry form. Give us the model and working conditions so we can check the equipment and supporting accessories together.
| Manufacturer | DVP |
|---|---|
| Equipment type | Industrial Vacuum Systems |
| End / ultimate pressure | 0.006 or 0.009 mbar, model-dependent; measured at booster inlet — absolute |
| Model | CBL Booster Systems |
| Documented configurations | 106/300, 205/500, 305/500, 305/1000, 2x305/1500, 2x305/2000, 3x305/3000 |
| Pump arrangement | BCA lobe booster with LC primary pump(s) |
| Capacity at 5 mbar | 239–3100 m³/h at 50 Hz; 246–3125 m³/h at 60 Hz, depending on configuration and stated curve limits |
Send the pump model and part number when asking about a replacement. Compatibility depends on the equipment and operating conditions.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
What to check in your quotation · Delivery · Returns and faults
DVP CBL Booster Systems
Prefer to talk? 01692 660 117 · [email protected]
We use your details to respond to your enquiry. Read our privacy policy.

DVP

MIL'S
INDUSVAC 1E 40.R autonomous and compact vacuum systems is dedicated to the centralised vacuum production.
View specifications
MIL'S
INDUSVAC 2 autonomous and compact vacuum system is dedicated to the centralised vacuum production.
View specifications
MIL'S
INDUSVAC 2 autonomous and compact vacuum system is dedicated to the centralised vacuum production.
View specificationsCompare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino