Hot Cathode / Pirani Ultra-high Vacuum Gauges
- Measurement principle
- Pirani and Bayard–Alpert; gas-dependent
- Measuring range
- 1000 to 5 × 10⁻¹⁰ mbar
- Pressure reference
- Absolute
The Edwards AIM200 active inverted magnetron vacuum gauge measures vacuum using cold-cathode inverted magnetron technology. Select the flange, output and materials for the pressure range, gas and system controller.
Manufacturer photograph of an analogue AIM200 gauge. Flange and connection choices are confirmed for the selected configuration.
Part of the Edwards APG200, AIM200 and WRG200 vacuum gauges family. Compare the range and other model options.
Tell us the configuration and quantity you need. Include your process requirements if you would like help with selection.
View quote listThe Edwards AIM200 active inverted magnetron vacuum gauge measures vacuum using cold-cathode inverted magnetron technology. Select the flange, output and materials for the pressure range, gas and system controller.
| Specification | Details |
|---|---|
| Measurement principle | Cold-cathode inverted magnetron |
| Measurement range | 1 × 10⁻⁹–1 × 10⁻² mbar |
| Supply voltage | 15–48 V DC |
| Output choices | Analogue or RS232/RS485; configuration-specific |
| Operating temperature | 0–50 °C |
| Bakeout | 150 °C with electronics removed |
| Service | Replaceable measuring tube and electronics |
| Specification | Details |
|---|---|
| D2G0021100 | NW25, standard analogue RJ45 |
| D2G0041100 | DN40CF, standard analogue RJ45 |
| D2G0020200 | NW25, RS485, 9-pin D-sub |
| D2G0025200 | NW25, RS232, 9-pin D-sub |
Measurement range is not an accuracy guarantee across the whole span. These gauge principles are gas dependent; retain the manufacturer’s gas correction and accuracy conditions. Protect the sensing element from unsuitable contamination and choose materials for the process. Bakeout to 150 °C requires removal of the electronics.
The nitrogen accuracy specification is less than 30% of measured value from 10⁻⁹ to 10⁻² mbar. Use a suitable rough-vacuum gauge alongside AIM200 when monitoring from atmosphere. Follow the manufacturer’s ignition and operating procedures.
Analogue RJ45 versions and RS232/RS485 D-sub versions are distinct configurations. Connector shape, transfer function, supply and set-point option must all match the receiving controller. The listed standard analogue builds can be selected with compatible Edwards gauge controllers; confirm compatibility for the complete gauge/controller pair. Gauges, cables and controllers are separately specified.
State the pressure range, gas species, flange, output, cable length and calibration requirement. See vacuum gauge calibration for ongoing measurement support.

Source: 3601-0754-01-AIM200-Datasheet, supplied from the manufacturer’s official website. This model-level listing retains configuration choices; the exact order reference, included equipment and lead time are confirmed in the quotation.
Explore the AIM200 range and Edwards brand guide. Compare vacuum gauges and controllers, plan gauge calibration, or discuss servicing.
For AIM200 Active Inverted Magnetron Vacuum Gauge, include working pressure, required flow or chamber volume, gas and vapour load, operating hours, electrical supply and connections. For a replacement, send the complete nameplate and serial number so the configuration can be checked.
| Manufacturer | EDWARDS |
|---|---|
| Equipment type | High & Ultra-high Vacuum Gauges |
| Measurement principle | Cold-cathode inverted magnetron |
| Measurement range | 1 × 10⁻⁹–1 × 10⁻² mbar |
| Supply voltage | 15–48 V DC |
| Output choices | Analogue or RS232/RS485; configuration-specific |
| Operating temperature | 0–50 °C |
| Bakeout | 150 °C with electronics removed |
| Service | Replaceable measuring tube and electronics |
Send the pump model and part number when asking about a replacement. Compatibility depends on the equipment and operating conditions.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
What to check in your quotation · Delivery · Returns and faults
Edwards AIM200 Active Inverted Magnetron Vacuum Gauge
Prefer to talk? 01692 660 117 · [email protected]
We use your details to respond to your enquiry. Read our privacy policy.

LEYBOLD

LEYBOLD
Compare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino