LEYBOLD
Leybold RUVAC WA / WAU 501 Roots Vacuum Booster
- Nominal displacement at 50 Hz
- 505 m³/h
- Ordering options
- 7 manufacturer codes — see configuration table
- Nominal connection size
- DN 63; flange standard confirmed for version
The DVP BCA Lobe Boosters is part of the DVP lobe vacuum boosters range. The documented capacity is 279–2887 m³/h at 50 Hz; 334–3465 m³/h at 60 Hz. Ask Girovac to match the configuration to your duty and electrical supply.
Part of the DVP BCA boosters & CBL packages family. Compare the range and other model options.
Tell us the configuration and quantity you need. Include your process requirements if you would like help with selection.
View quote listThe DVP BCA Lobe Boosters is part of the DVP lobe vacuum boosters range. The documented capacity is 279–2887 m³/h at 50 Hz; 334–3465 m³/h at 60 Hz. Ask Girovac to match the configuration to your duty and electrical supply.
A lobe booster works with a primary pump to improve pumping speed over part of the pressure range. Select the pair from the system curve and respect differential-pressure and start-up limits. A booster is not a stand-alone replacement for the backing pump.
A Roots-type booster must be selected with its primary pump and control arrangement. Maximum differential pressure is not an ultimate-vacuum rating. The gas chamber is dry; gears, bearings and shaft sealing have separate lubricant requirements.
| Specification | Manufacturer data |
|---|---|
| Model | DVP BCA Lobe Boosters |
| Models | BCA 300, 500, 1000, 1500, 2000, 3000 |
| Nominal pumping capacity | 279–2887 m³/h at 50 Hz; 334–3465 m³/h at 60 Hz |
| System requirement | Suitable primary/backing pump required |
| Versions | Standard motor configuration or AdaptShield; specify the required version |
Values apply to the stated model and conditions. Where two figures are shown, follow the 50 / 60 Hz order in the label. Confirm the motor, connections and supplied accessories in your quotation.
| Model | Nominal capacity 50 / 60 Hz | Motor power 50 / 60 Hz (standard version) |
|---|---|---|
| BCA 300 | 279 / 334 m³/h | 1.1 / 1.5 kW |
| BCA 500 | 504 / 605 m³/h | 2.2 / 3 kW |
| BCA 1000 | 1008 / 1210 m³/h | 4 / 5.5 kW |
| BCA 1500 | 1433 / 1720 m³/h | 4 / 5.5 kW |
| BCA 2000 | 2045 / 2454 m³/h | 5.5 / 7.5 kW |
| BCA 3000 | 2887 / 3465 m³/h | 7.5 / 11 kW |
Download the original DVP BCA Lobe Boosters datasheet (PDF). The original document includes its revision information and any additional model-specific conditions.

A Pirani vacuum transducer is a useful starting point for measuring pump-down into lower pressures. Check its measuring range, gas correction and process compatibility. Measure at the chamber or point of use when that is the pressure your process depends on. Gauge calibration can be specified around the operating range and required test points.
Use the complete model, serial number and manufacturer oil specification. Different suffixes and gear compartments can require different lubricants. See vacuum oils and greases and send the nameplate details when requesting parts.
Send the model, required flow at working pressure, gas or vapour, operating hours, electrical supply and any installation restrictions. For a replacement, include a nameplate photograph. We will confirm the proposed configuration, price and lead time before ordering.
Discuss the complete duty when reviewing industrial vacuum systems. A central installation also needs matched controls, filtration, pipework and pressure measurement; pump capacity alone is not the system specification.
Call 01692 660 117 or use the product enquiry form. Give us the model and working conditions so we can check the equipment and supporting accessories together.
| Manufacturer | DVP |
|---|---|
| Equipment type | Lobe Vacuum Boosters |
| Nominal pumping capacity | 279–2887 m³/h at 50 Hz; 334–3465 m³/h at 60 Hz |
| Model | BCA Lobe Boosters |
| Models | BCA 300, 500, 1000, 1500, 2000, 3000 |
| System requirement | Suitable primary/backing pump required |
| Versions | Standard motor configuration or AdaptShield; specify the required version |
Send the pump model and part number when asking about a replacement. Compatibility depends on the equipment and operating conditions.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
What to check in your quotation · Delivery · Returns and faults
DVP BCA Lobe Boosters
Prefer to talk? 01692 660 117 · [email protected]
We use your details to respond to your enquiry. Read our privacy policy.

LEYBOLD

LEYBOLD

LEYBOLD

LEYBOLD
Compare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.
Copyright © 2026 Girovac Ltd | Registered in England and Wales Number: 01758137 | Cookie Policy | Privacy Policy | Delivered by Postino