DVP
DVP CPA3H Vacuum System
- Nominal pumping capacity
- 75–915 m³/h (50 Hz; configuration-dependent)
- Model
- CPA3H
- Pump arrangement
- 3 lubricated rotary vane pumps
The DVP CPAP Duplex is a vacuum system. The documented capacity is 310–500 m³/h (50 Hz; model-dependent). Total final pressure is 150 mbar with PA 155; 200 mbar with PA 315. Ask Girovac to match the configuration to your duty and electrical supply.
Part of the DVP CPA, CPAP, CPV & XC systems family. Compare the range and other model options.
Tell us the configuration and quantity you need. Include your process requirements if you would like help with selection.
View quote listThe DVP CPAP Duplex is a vacuum system. The documented capacity is 310–500 m³/h (50 Hz; model-dependent). Total final pressure is 150 mbar with PA 155; 200 mbar with PA 315. Ask Girovac to match the configuration to your duty and electrical supply.
For a packaged or central vacuum installation, list each user, its operating pressure and which users run together. Agree the receiver, controls, filtration and standby requirement as part of the quotation. Allow for distribution losses when specifying the flow and pressure required at each outlet.
Centralised claw-pump package. State simultaneous demand, required pressure, redundancy and control requirements. Include the flow and pressure required at each outlet.
| Specification | Manufacturer data |
|---|---|
| Model | DVP CPAP Duplex |
| Pump arrangement | 2 dry claw pumps |
| Nominal pumping capacity | 310–500 m³/h (50 Hz; model-dependent) |
| Total final pressure (absolute) | 150 mbar with PA 155; 200 mbar with PA 315 |
| Instrumentation | Absolute-pressure sensor, control panel and individual pump isolation |
Values apply to the stated model and conditions. Where two figures are shown, follow the 50 / 60 Hz order in the label. Confirm the motor, connections and supplied accessories in your quotation.
| Configuration | Pumps | Capacity at 50 Hz | Total final pressure | Installed motor power at 50 Hz |
|---|---|---|---|---|
| CPAP 2×155 | 2 × PA 155 | 310 m³/h | 150 mbar | 2 × 3.0 kW |
| CPAP 2×315 | 2 × PA 315 | 500 m³/h | 200 mbar | 2 × 5.5 kW |
Download the original DVP CPAP Duplex datasheet (PDF). The original document includes its revision information and any additional model-specific conditions.

Compare DVP XC 405, DVP XC 605, DVP XC 905. Check the working pressure, capacity and motor rather than choosing by the model number alone. Browse the full DVP range.
For suitable rough-vacuum duties, compare industrial vacuum dial gauges. Where a display, output or control signal is needed, review digital vacuum meters and vacuum transducers. Measure at the chamber or point of use when that is the pressure your process depends on. Gauge calibration can be specified around the operating range and required test points.
Use the complete model, serial number and manufacturer oil specification. Different suffixes and gear compartments can require different lubricants. See vacuum oils and greases and send the nameplate details when requesting parts.
Send the model, required flow at working pressure, gas or vapour, operating hours, electrical supply and any installation restrictions. For a replacement, include a nameplate photograph. We will confirm the proposed configuration, price and lead time before ordering.
Call 01692 660 117 or use the product enquiry form. Give us the model and working conditions so we can check the equipment and supporting accessories together.
| Manufacturer | DVP |
|---|---|
| Equipment type | Industrial Vacuum Systems |
| Nominal pumping capacity | 310–500 m³/h (50 Hz; model-dependent) |
| End / ultimate pressure | 150 mbar with PA 155; 200 mbar with PA 315 — absolute |
| Model | CPAP Duplex |
| Pump arrangement | 2 dry claw pumps |
| Instrumentation | Absolute-pressure sensor, control panel and individual pump isolation |
Send the pump model and part number when asking about a replacement. Compatibility depends on the equipment and operating conditions.
Confirm the exact version, electrical supply and connections. Ask whether oil, filters, fittings, cables or controllers are included or separately specified.
Availability, lead time and the applicable warranty are confirmed for your quotation. A catalogue listing does not reserve stock.
What to check in your quotation · Delivery · Returns and faults
DVP CPAP Duplex Vacuum System
Prefer to talk? 01692 660 117 · [email protected]
We use your details to respond to your enquiry. Read our privacy policy.

DVP

MIL'S

DVP

MIL'S
Compare the stated conditions as well as the values. A missing specification is not a zero rating; confirm suitability with Girovac.